Extension cords

1. Grounded tools require a
three wire extension cord.
Double Insulated tools can use either
a two or three wire extension cord.
2. As the distance from the supply outlet
increases, you must use a heavier gauge
extension cord. Using extension cords with
inadequately sized wire causes a serious
drop in voltage, resulting in loss of power
and possible tool damage. (See Table A.)
3. The smaller the gauge number of
the wire, the greater the capacity of
the cord. For example, a 14 gauge
cord can carry a higher current than
a 16 gauge cord. (See Table A.)
4. When using more than one extension cord
to make up the total length, make sure
each cord contains at least the minimum
wire size required. (See Table A.)
5. If you are using one extension cord for more
than one tool, add the nameplate amperes
and use the sum to determine the required
minimum cord size. (See Table A.)
6. If you are using an extension cord
outdoors, make sure it is marked with the
suffix "W-A" ("W" in Canada) to indicate
it is acceptable for outdoor use.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V
Volts
~
Alternating Current
A
Amperes
Item 95020
For technical questions, please call 1-888-866-5797.
7. Make sure the extension cord is properly
wired and in good electrical condition.
Always replace a damaged extension
cord or have it repaired by a qualified
electrician before using it.
8. Protect the extension cords from
sharp objects, excessive heat,
and damp or wet areas.
Table A: Recommended Minimum
Wire Gauge for Extension cords*
(120/240 Volt)
EXTENSION cORD
NAMEpLATE
AMpERES
(at full load)
0 – 2.0
18
2.1 – 3.4
18
3.5 – 5.0
18
5.1 – 7.0
18
7.1 – 12.0
18
12.1 – 16.0
14
16.1 – 20.0
12
* Based on limiting the line voltage drop to
five volts at 150% of the rated amperes.
n 0 xxxx/min.
No Load Revolutions per Minute (RPM)
WARNING marking concerning Risk
of Eye Injury. Wear ANSI-approved
safety goggles with side shields.
Read the manual before
set-up and/or use.
WARNING marking
concerning Risk of Fire.
Do not cover ventilation ducts.
WARNING marking concerning
Risk of Electric Shock.
Maintain Power cord properly.
LENGTH
18
18
18
16
18
18
16
14
18
16
14
12
16
14
12
12
14
12
10
-
12
10
-
-
10
-
-
-