Rs-485 Communication Control; Operating Your Camera; Menu Configuration - Samsung SID-560 User Manual

Supreme image 560tvl, 128x high resolution wdr v/f dome camera
Hide thumbs Also See for SID-560:
Table of Contents

Advertisement

Connection
When the resistance value of copper wire is at [20˚C(68˚F)]
Copper wire size (AWG)
#24(0.22mm
2
)
#22(0.33mm
Resistance (Ω/m)
0.078
Voltage Drop (V/m)
0.028
• As shown in the table above, voltage decreases as the wire gets longer. Therefore use of
an excessively long adaptor output line for connection to the camera may affect the
performance of the camera.
*Standard voltage for camera operation : DC 12V ± 10%
*There may be some deviation in voltage drop depending on the type of wire and the manufacturer.
Notes
• Be sure to connect power only after all the installation is complete.
• Note that DC adaptor is not supplied with camera.
• Ground should be connected to the GND terminal.

RS-485 communication control

Connecting to RS-485 Control Cable
Using a RS-485 communication, it will be able to control the OSD menu at the SAMSUNG
TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera and serial
cable
EX) S ERIAL PORT OF THE PC(COM1) → SERIAL CABLE → RS-485 CONVERTER → RS-485 CONTROL CABLE
(2) The case which it controls from the DVR or System Controller
It connects the RS-485 control cable in the connection terminal of 485 control boards which
are connected with the DVR or System Controller.
485 Control Board Connection Port
(+) CONNECTION TERMINAL
(- ) CONNECTION TERMINAL
14
COLOR DOME CAMERA
2
)
#20(0.52mm
2
)
#18(0.83mm
2
)
0.050
0.030
0.018
0.018
0.011
0.006
CONTROL CABLE
SPEC
RED (TRX+)
RS-485+
WHITE(TRX-)
RS-485-
RS-485 Control Port
RED (TRX+)
WHITE (TRX-)
User's Manual
* RS-485 Communication establishment initial value
Item
Camera ID
BAUD RATE
Initial value
1
9600
Notes
• W hen you construct external control systems for a camera control, please use to the SAMSUNG
TECHWIN PROTOCOL or PELCO-D PROTOCOL.
• W hen you connecting to RS-485 control cable, please peel off the outer skin inside the RS-485
control cable.
• I n case of SCC-101 connection, change communication mode to 『8-E-1』 at 『Communication
configuration』menu. (For more information, refer to SCC-101 manual.)

Operating Your Camera

Menu Configuration

Setup Menu
LENS
●DC
●SHUTTER
EXPOSURE
●RETURN
●ATW
WHITE BALANCE
●OUTDOOR
OFF
BACKLIGHT
HLC
SSNR
ON
COLOR
DAY/NIGHT
IMAGE ADJUSTMENT
●V-REV
(IMAGE ADJ.)
●SHARPNESS
●CAMTITLE...
SPECIAL
●DIS...
●RESET...
EXIT
COLOR DOME CAMERA
UART MODE
PET PKT
8-NONE-1
ENABLE
●AGC
●SENS-UP
●MANUAL
●AWC→SET
●INDOOR
WDR
BLC
OFF
B/W
AUTO
●H-REV
●D-ZOOM
●RETURN
●MOTION DET...
●PRIVACY...
●COMM ADJ...
●LANGUAGE
●RETURN
15
User's Manual

Advertisement

Table of Contents
loading

Table of Contents