Other Fault Codes; Testing The Exhaust Sensor; Door Switch Adjustment; Brown Out - Fisher & Paykel AD55 Service Manual

Clothes dryer
Table of Contents

Advertisement

Other Fault Codes –
There are many other fault codes, these refer
to faults on the PCB assembly itself. The
PCB assembly will have to be replaced in
these cases.
Record the fault code displayed and return
with the PCB assembly to Fisher & Paykel for
repair.
TESTING
THE
SENSOR
At normal room temperature (25
resistance of the thermistor will be approx
o
2000 ohm and at O
Description –
The Exhaust Sensor consists of a device
called a thermistor, which is mounted on a
small piece of PCB attached to the wiring
harness.
Use a multi meter to test the resistance of the
sensor.
The thermistor is a device that changes its
electrical
resistance
temperature.
The higher the temperature,
the higher the resistance thermistor.
DOOR SWITCH
ADJUSTMENT
The door switch should be adjusted so that
the door has opened no more than 40 mm –
65 mm before the PAUSE mode is activated
and the dryer stops.
Adjust door switch by removing hinge cover
(two screws). Loosen two screws holding the
switch.
If the door switch is not activated the
ED55/56 will sound a warning tone when the
START/PAUSE button is pressed.

BROWN OUT

If the mains voltage falls below a certain
voltage, even for a short period of time, it is
known as a brown out.
EXHAUST
o
C) the
C 1640 ohms.
according
to
If this mains voltage falls below this minimum
voltage the Electronic Control System will not
be able to function correctly. The Electronic
Control System therefore is fitted with a
circuit that will automatically turn the dryer off.
The voltage at which this happens is between
165 – 170 volts.
During Brown Out the dryer will simply switch
off.
The dryer can be restarted by simply
using the POWER button.
the
- 24 -