cLeanInG anD MaIntenance

turn off gas before servicing fireplace. It
is recommended that a qualified service
technician perform these check-ups at the
beginning of each heating season
Burner, pILOt anD cOntrOL cOMpart-
Ment
Keep the control compartment, logs, and burner areas
surrounding the logs clean by vacuuming or brushing at
least twice a year. Make sure the burner porting, pilot air
opening and burner air opening are free of obstructions
at all times.

pILOt FLaMe

The flames from the pilot should be visually checked as
soon as the heater is installed and periodically during
normal operation. the pilot flame must always be pres-
ent when the fireplace is in operation. Figure 66. The
pilot flame has three or four distinct flames, one engulfing
the thermopile, one engulfing the thermocouple, and the
remaining reaching to the main burners.
Burner
Inspect area around the injector. Remove any lint or foreign
material with a brush or vacuum.

Burner FLaMe

The flames from the burner should be visually
checked as soon as the heater is installed and peri-
odically during normal operation. In normal opera-
tion, at full rate, and after operating for about 15 to
30 minutes, the flame should be yellow and slightly
taller than the rear log. Figure 67
If the flame is blue and only in the center, turn off
unit and let cool. After unit is cool, remove logs and
check to make sure the back holes in the burner are
not covered with rock wool. If the back holes are
clear, add more rock wool to the center of the burner.
Replace logs.
nOte: The type of installation, vent system configuration,
and wind effects may cause the flame patterns to vary.
73D0129
DVKHL Series Gas Fireplace
Signature
command
System pilot
Thermocouple
Millivolt control
pilot
Figure 66 -
Pilot Flame
FP1943
pilot flame
Figure 64 -
Burner Flame Appearance
LG601
flame appearance
Sensor
Thermopile
FP2453
Thermopile
FP2453
hooded pilot flames
FP1943
LG601
49