Converting 3 Wire To 4 Wire Power Cord; Anti-Tip Bracket Installation - Amana ARTSC8650 Series Owner's Manual

Convection self-cleaning slide-in electric range
Table of Contents

Advertisement

Available languages

Available languages

Converting 3 Wire to 4 Wire Power Cord

1. Remove rear wire cover.
2. Remove bottom strain relief screw and retain for further
use.
3. Remove screw/hex nuts from terminal block and retain for
further use.
4. Remove all 3-wire or cable leads from the terminal block
and proceed to remove the power cord from the unit by
pulling in a downward motion so that cord is removed
from strain relief.
5. Remove the grounding strap attached to the center
terminal on the terminal block.
• Grounding strap is not needed for this installation.
• Remove green ground screw and retain for future use.
6. To install the 4-wire cord, please follow step 4 through
step 9 of Installing 4 Wire Cord .
7. Reinstall rear cover and secure it with screw removed
earlier.

Anti-tip Bracket Installation

To reduce risk of range tipping, secure range with a
properly installed anti-tip bracket.
1. Remove storage drawer from range.
• See "Removing Storage Drawer" section.
2. Unscrew leveling legs so when range is moved into
position range top clears counter top.
• Left or right rear leveling leg must extend at least ¼ inch
to engage bracket.
• Anti-tip bracket can be installed on either right or left
rear leveling leg.
3. Move range to where it will be installed.
4. Position anti-tip bracket.
• With range in position, reach through storage
drawer opening and slide anti-tip bracket on either
left or right rear leveling leg. Slide leg into V-shaped
notch in bracket.
5. Mark location of side and front of anti-tip bracket on
floor.
6. Remove anti-tip bracket and range from opening.
7. Position anti-tip bracket according to lines marked on
floor.
8. Mark 2 hole locations in anti-tip bracket.
9. Drill 2 holes.
• If drilling into wood, use a
• If drilling into concrete, use a
bit and insert plastic anchors.
10. Secure bracket to floor using screws supplied.
11. Slide range into position.
• See "Level Range" section of manual.
12. Confirm anti-tip bracket is engaged with range leveling
leg and replace storage drawer.
10
or
3
/
inch drill bit.
32
3
/
inch masonry drill
16

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Arhsc8750 series

Table of Contents