6.4

Error Codes and Diagnostic Codes

Number of
flashes
1
2
3
30
Fault
Impact on
Scooter
Battery needs
Will drive
charging
Battery voltage
Drive inhibited
too low
Lifter raised
Driving speed
reduced
Battery voltage
Drive inhibited
too high
Notes
Battery charge is running low. Recharge
the batteries as soon as possible.
Battery charge is empty. Recharge the
batteries.
If the scooter is left off for a few minutes,
battery charge may recover sufficiently to
allow driving for a short period of time.
You should only ever do this in an
emergency, as this deep-discharges the
batteries!
Lower lifter completely.
Battery charge is too high. If a charger is
plugged in, unplug it.
The electronic system charges the
batteries when travelling down slopes or
decelerating. Excessive charging in this
manner may cause this fault. Turn the
scooter power off and then back on
again. Turn on the lighting system to use
power.