100 Mb Fiber Transceiver Characteristics
Fiber Length
TX Power Min/Max
RX Sensitivity Max
Wavelength Min/Max
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Regulatory Approvals:
Safety: UL Listed per ANSI/ISA-12.12.01-2000 (US and Canada) and listed for use in Class I, Div 2,
Groups A, B, C, and D, T4A
EMI: EN61000-6-4, EN55011 – Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
EMS: EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)
IEC 61000-4-8 (Power-frequency Magnetic Field)
IEC 61000-4-11 (Voltage Dips and Interruptions)
Revision 050908
2km*
15km**
-19dBm/-14dBm
-15dBm/-7dBm
-32dBm
-29dBm
1310nm
1310nm
40km**
80km**
-5dBm/0dBm
-5dBm/0dBm
-34dBm
-34dBm
1310nm
1550nm