Stove Installation

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' (2.134M) tall, it is
considered an alcove installation. Because of the reduced height, the special installation requirements
listed below must be met.
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls
and a ceiling that are 3 1/2" (89mm) thick of a non-combustible material (brick, stone, or concrete -
see Figure 7). This non-combustible material must be spaced and ventilated at least 1" (25mm) off of
all combustible materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls
and ceiling. All other alcoves are considered combustible. The clearances below must be met:
Minimum Clearance
(See Figure 7 below)
A
Sidewall to stove
B
Back wall to stove
D
Connector to sidewall
E
Connector to back wall
G
Maximum depth of alcove
H
Minimum width of alcove
J
Minimum height of alcove
Non-Combustible Alcove
(a) Non-Combustible (brick)
(b) Air Space with non-combustible
reinforcement
(c) Combustible material
Min. 1"
(25mm)
c
© Travis Industries
Min. 3 1/2"
(89mm)
a
b
(for qualified installers only)
Combustible
Alcove
12 ¾"
11 ¾"
26"
12"
48" (1220mm)
59"
84" (2134mm)
* For bypass operation
d
a
j
h
100-01282_000
Non-Combustible
Alcove
4-1/2" (left side)
8" (right side *)
4"
17-3/4"
4-1/4"
48" (1220mm)
50"
6" above stove top
e
b
g
13
Figure 7
4111128