Connecting The Drain Hose To The Outdoor Unit; Fixing The Unit In Position - Samsung ACH2400C Owner's Instructions & Installation Manual

Cassette-type air conditioner (cool and heat)
Hide thumbs Also See for ACH2400C:
Table of Contents

Advertisement

Connecting the Drain Hose to the Outdoor Unit

50mm
(2" )

Fixing the Unit in Position

(26")
660mm
50
E-
When using the air conditioner in the heating mode, ice may accumulate.
During de-icing, the condensed water must be drained off safely.
Consequently, you must install a drain hose on the outdoor unit,
following the instructions below.
1
Make space more than 50mm(2in) between the bottom of the outdoor unit
and the ground for installation of the drain hose, as shown in figure.
2
Insert the drain plug into the hole on the underside of the outdoor unit.
3
Connect the drain hose to the drain plug.
4
Ensure that the drained water runs off correctly and safely.
The outdoor unit must be installed on a rigid and stable base to avoid any
increase in the noise level and vibration, particularly if the outdoor unit is to
be installed close to a neighbour. If it is to be installed in a location exposed to
strong winds or at a height, the unit must be fixed to an appropriate support
(wall or ground).
1
Position the outdoor unit so that the air flow is directed towards the
outside.
2
Attach the outdoor unit to the appropriate support using anchor bolts.
3
If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit, so that the fan can operate correctly.