Summary of Contents for Samsung AC HCADKH Series

  • Page 1 CAC_Global Duct Latin America_IM_EN_04680A-02.indd 32 2014-09-04 오전 9:17:34...
  • Page 2 ACHCADKH ACHCADNH Air Conditioner installation manual This manual is made with 100 % recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. EN ES PT DB68-04680A-02 CAC_Global Duct Latin America_IM_EN_04680A-02.indd 33 2014-09-04 오전 9:17:34...
  • Page 3: Table Of Contents

    Contents PREPARATION Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Preparation for outdoor unit installation .
  • Page 4: Preparation

    In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy .
  • Page 5 Safety precautions Installing the unit IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines . Always disassemble the electric lines before the refrigerant tubes . Upon receipt, inspect the product to verify that it has not been damaged during transport . If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer .
  • Page 6: Preparation For Outdoor Unit Installation

    Preparation for outdoor unit installation The air conditioner uses R-410A refrigerant . A Type: AC030HCADKH / AC036HCADKH / AC036HCADNH / AC042HCADKH / AC042HCADNH (Unit : mm)  Heat pump B Type: AC048HCADKH / AC048HCADNH  Heat pump Moving the Outdoor Unit by Wire Rope Fasten the outdoor unit by two 8 m or longer wire ropes as shown at the figure . To prevent from damage or scratches, insert a piece of cloth between the Wire rope outdoor unit and rope, then move the unit .
  • Page 7: Deciding On Where To Install The Outdoor Unit

    Air Guide Duct (This product is not Stereo provided by Samsung) 200 mm f If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position . f Make sure that the water dripping from the drain hose runs away correctly and safely .
  • Page 8 f When installing the outdoor unit near seashore, make sure it is not directly exposed to sea breeze . If you can not find a adequate place without direct see breeze, protection wall should be constructed . f Install the outdoor unit in a place (such as near buildings etc . ) where it can be prevented from sea breeze which can damage the outdoor unit .
  • Page 9 Deciding on where to install the outdoor unit Space Requirements for Outdoor Unit When installing 1 outdoor unit ❋ ❋ When the air outlet is opposite the wall ❋ ❋ When the air outlet is towards the wall 2000 or more 300 or more 600 or more ❋ ❋ When 3 sides of the outdoor unit are blocked by the wall ❋...
  • Page 10 When installing more than 1 outdoor unit (Unit : mm) ❋ ❋ When the air outlet is towards the wall 300 or more 600 or more 600 or more 600 or more ❋ ❋ When 3 sides of the outdoor unit are blocked by the wall 300 or more 300 or more 600 or more...
  • Page 11: Installation

    INSTALLATION Outdoor unit installation The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support(wall or ground) .
  • Page 12: Connecting The Cable

    Connecting the cable Two electronic cables must be connected to the outdoor unit . f The connection cord between indoor unit and outdoor unit . f The power cable between outdoor unit and auxiliary circuit breaker . f Specially for Russian and European market, before installation, the supply authority should be consulted to determine the supply system impendance to ensure compliance .
  • Page 13 Connecting the cable Power Cable Specifications f The power cable is not supplied with air conditioner . - Select the power supply cable in accordance with relevant local and national regulations . - Wire size must comply with the applicable local and national code . - Specifications for local wiring power cord and branch wiring are in compliance with local cord .
  • Page 14 Between Indoor unit and Outdoor unit Connection Cable Specifications(Common in use) Power supply Communation Cable Power supply Max/Min(V) Indoor Power Cable , 3wires 1Φ, 220-240 V, 60Hz ±10 % 2 . 5  mm ² 0 . 7 5~1 . 5  mm², 2wires f Power Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord .
  • Page 15 Connecting the cable Wiring Diagram of Power Cable When using ELB for 1 phase and 3 phase f 1 phase 1(L) 2(N) Cable tie Electrical Power Supply Indoor Power component box MCCB Cable clamp Communication cable Main power cable MCCB f 3 phase 1(L) 2(N) L1(R) L2(S) L3(T) Indoor Unit Cable tie ❋ ❋ The appearance of the unit may be Cable clamp different from the picture depending on the model .
  • Page 16 Silence mode controller wiring diagram Outdoor unit Silence Mode Controller Wiring Diagram of Connection Cord 1 phase 3 phase Indoor Unit Indoor Unit 1(L) 1(L) 2(N) 2(N) 1(L) 2(N) L1(R) L3(T) 1(L) 2(N) L2(S) Cable tie Cable tie Indoor Power Cable clamp Communication cable Main power cable Indoor Power Communication cable 3 Phase 4 Wires power cable (AC 380V) Cable clamp •...
  • Page 17 Connecting the cable Connecting the Power Terminal f Connect the cables to the terminal board using the compressed ring terminal . f Cover a solderless ring terminal and a connector part of the power cable and then connect it . Silver solder Nominal Nominal dimensions dimensions Standard Standard...
  • Page 18 Refrigerant piping system Maximum allowable length Items Single installation AC030HCADKH Applicable outdoor unit models AC036HCAD✴H AC048HCAD✴H AC042HCAD✴H Total pipe length (L1+…+Ln+1+a+b) Main pipe (L1) 50 m 75 m Max . distance among indoor units (D) Max . length after branch Max . height difference between outdoor and indoor units (h1) 30 m 30 m Max .
  • Page 19: Adding Refrigerant (R-410A)

    Adding refrigerant (R-410A) The outdoor unit is loaded with sufficient refrigerant for the standard piping . Thus, refrigerant must be added if the piping is lengthened . This operation can only be performed by a qualified refrigeration specialist . For quantity of adding refrigerant, refer to page 19 .
  • Page 20: Connecting Up And Removing Air In The Circuit

    Connecting up and removing air in the circuit • When installing, make sure there is no leakage . When recovering the refrigerant, ground the compressor first before removing the connection pipe . If the refrigerant pipe is not properly connected and the compressor CAUTION works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high .
  • Page 21 Connecting up and removing air in the circuit 5 . Purge the air from the system using vacuum pump for about 10 minutes. f Close the valve of the low pressure side of manifold gauge clockwise . f Make sure that pressure gauge shows -0 . 1 MPa(-76cmHg) after about 10 minutes . This procedure is very important to avoid a gas leak . f Turn off the vacuum pump .
  • Page 22: Cutting/Flaring The Pipes

    Cutting/Flaring the pipes 1 . Make sure that you have the required tools available. (pipe cutter, reamer, flaring tool and pipe holder) 2 . If you wish to shorten the pipes, cut it with a pipe cutter, taking care to ensure that the cut edge remains at a 90° angle with the side of the pipe. Refer to the illustrations below for examples of edges cut correctly and incorrectly. Oblique Rough Burr 3 . To prevent any gas from leaking out, remove all burrs at the cut edge of the pipe, using a reamer. 4 . Slide a flare nut on to the pipe and modify the flare. Outer Diameter (D) Depth (A) ø6 . 3 5 mm(1/4") 1 . 3 mm ø9 . 5 2 mm(3/8") 1 . 8 mm ø12 . 7 0 mm(1/2") 2 .
  • Page 23: Performing Leak Tests

    Performing leak tests LEAK TEST WITH NITROGEN (before opening valves) In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R-410A, it’s responsable of installer to pressurize the whole system with nitrogen (using a cylinder with pressure reducer) at a pressure above 40 bar (gauge) . LEAK TEST WITH R-410A (after opening valves) B(Liquid) A(Gas)
  • Page 24: Insulation

    Insulation Once you have checked that there are no leaks in the system, you can insulate the piping and hose . 1 . To avoid condensation problems, place an insulator around each refrigerant pipe. • When insulate the pipe, be sure to overlap the insulation . NOTE • When insulating the pipe, use non-slit insulator . CAUTION 2 .
  • Page 25: Using Stop Valve

    Using stop valve To Open the Stop Valve 1 . Open the cap and turn the stop valve counterclockwise by using a hexagonal wrench. 2 . Turn it until the axis is stopped. Service port • Do not apply excessive force to the stop valve and always use special instruments . Otherwise, the stopping box can be damaged and the NOTE back sheet can leaks . Axis •...
  • Page 26: Pump Down Procedure

    Pump down Procedure Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area . 1 . Remove the cap from the low pressure side. 2 . Turn the low pressure side valve clockwise to close and connect a pressure gauge (low pressure side) to the service valve, and open the valve again. B(liquid) A(gas) 3 . Set the unit to the cooling Test mode by pushing K2 button (Check if the compressor is operating.) 4 . Turn the high pressure side valve counter clockwise to close. 5 . When the pressure gauge indicates “0” turn the low pressure side valve counter clockwise to close.
  • Page 27: Checking Correct Grounding

    Checking correct grounding If the power distribution circuit does not have a grounding or the grounding does not comply with specifications, an grounding electrode must be installed . The corresponding accessories are not supplied with the air conditioner . 1 . Select an grounding electrode that complies with the specifications given Carbon in the illustration.
  • Page 28: Testing Operations

    Testing operations 1 . Check the power supply between the outdoor unit and the auxiliary circuit breaker. f 1 phase power supply : L, N f 3 phases power supply : R,S,T,N 2 . Check the indoor unit. 1) Check that you have connected the power and communication cables correctly . (If the power cable and communication cables one mixed up or connected incorrectly, the PCB will be damaged .
  • Page 29 Testing operations 6 . View Mode : When the K4 switch is pressed, you can see information about our system state as below. Short Display contents SEG1 SEG2 SEG3 SEG4 Unit push Order frequency Hundreds' digit Tens' digit Unit digit Current frequency Hundreds' digit Tens' digit Unit digit The number of current indoor units Hundreds' digit Tens' digit Unit digit The sensor for outdoor air intake + / - Tens' digit...
  • Page 30 7 . DIP switch option 1 2 3 4 1 2 3 4 SW508 SW507 f DIP switch(SW507) option On (default) Switch 1 Auto address Manual address Switch 2 Disable snow prevention control Enable snow prevention control Switch 3 Silence Mode option Switch 4 ❋...
  • Page 31: Troubleshooting

    Troubleshooting The table below give indication about self diagnostic routine . Some of error code requires activities exclusively for Authorized Service Center . Outdoor unit If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. Displayed Meaning Remarks Error Code PCB Assy Normal operation MAIN/INVERTER (MAIN : IndoorOutdoor : Green ON) (INVERTER : MAIN PCBINVERTER PCB : Green ON) Unit quantity miss matching between indoor and Check indoor quantity setting MAIN...
  • Page 32 Displayed Meaning Remarks Error Code PCB Assy Check indoor and outdoor MAIN GAS Leak error E554 unit model Check indoor and outdoor MAIN Capacity miss match between indoor and outdoor E556 unit model Option code miss matching among the indoors (only for MAIN Check indoor option code E557...