Adjusting the Burn Rate

Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Use the air control to
change the burn rate.
Low Burn
(air control closed)

Approximate Air Control Settings:

The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.

Ash Removal

Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, away from all combustible materials,
pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed,
ASHES
they should be retained in the closed container until all cinders have thoroughly cooled.
© Travis Industries
Operating Your Appliance
High Burn
(air control open)
100-01342
Overnight Burn
Pulled fully out
Medium Burn
Pulled fully out to 5/8" in
Medium High Burn
5/8" to all the way in
High Burn
Pushed all the way in