Firebox Location - MHSC 36STFL Installation And Operating Instructions Manual

Lo-rider designer vent-free fireboxes
Table of Contents

Advertisement

Lo-Rider Vent Free Fireboxes
Carefully select the best location for installation of your vent-free firebox. The following factors should
be taken into consideration.
Clearance to side wall, ceiling, woodwork, and windows. See Clearances and Height Require-
ments section below and on pages 8 and 9. Minimum clearances to combustibles must be
maintained.
Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air
registers for forced air furnaces/air conditioners, windows, or doors.
Installation must provide adequate ventilation and combustion air.
DO NOT INSTALL THIS FIREBOx IN A BATHROOM.
This firebox enclosure is approved for bedrooms on the condition that the unvented room heater
does not exceed 10,000 BTUs input and the room is properly sized for combustion air.
Location should be out of high traffic or windy or drafty areas.
DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE
OBJECTS ARE LESS THAN 36" FROM FRONT OF HEATER.
Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and
ventilation air.
Minimize modifications to existing construction. Refer to Figure 2 for location suggestions.
Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-
free firebox must be kept clear and free from these combustible materials.
Corner Right
Figure 2 -
Suggested Firebox Locations
6
Peninsula
See-Through
FP2885
fireplace locations
Corner
Left
Corner
Left
Corner
Right
FIREBOx LOCATIONS
FP885