Insulation Tests; No-Load Current Value - Hitachi D 10VF Technical Data And Service Manual

3/8” (10 mm) drills/1/2” (13 mm) drills
Hide thumbs Also See for D 10VF:
Table of Contents

Advertisement

8-5. Insulation Tests

On completion of reassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 MΩ or more with DC 500 V Megohm Tester
Dielectric strength: AC 2500 V/1minute, with no abnormalities

8-6. No-Load Current Value

After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
120
Current (A) Max.
3.0
--- 32 ---