Insulation Tests; No-Load Current Value - Hitachi DH 25PA Technical Data And Service Manual

Table of Contents

Advertisement

9-6. Insulation Tests

On completion of reassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 MΩ or more with DC 500 V Megohm Tester
Dielectric strength
: AC 4,000 V/1 minute, with no abnormalities
AC 2,500 V/1 minute, with no abnormalities

9-7. No-Load Current Value

After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
110
6.2
Current (A) Max.
115
120
5.9
5.7
--- 28 ---
220 V --- 240 V
• • • • • • • •
(and 110 V for U.K. products)
110 V --- 127 V
• • • • • • • •
(except for U.K. products)
127
220
5.4
3.1
230
240
3.0
2.8