Important Safety Information - 3Com SuperStack 3 Switch 3300 XM User Manual

3c16985b, 3c16987a, 3c16986a, 3c16988a
Hide thumbs Also See for SuperStack 3 Switch 3300 XM:
Table of Contents

Advertisement

36
A
A: S
PPENDIX
AFETY
Important Safety
Information
I
NFORMATION
Installation and removal of the unit must be carried out by qualified
I
personnel only.
If installing the Switch unit in a stack with SuperStack Hub units, the
I
Switch 3300 XM, SM, TM or MM unit must be installed below the
Hub units.
The unit should never be connected to an A.C. outlet (power supply)
I
without an earth (ground) connection.
The unit must be connected to an earthed (grounded) outlet to
I
comply with European safety standards.
Power Cord Set:
I
This must be approved for the country where it is used:
U.S.A. and
Canada
Denmark
Switzerland
The appliance coupler (the connector to the unit and not the wall
I
plug) must have a configuration for mating with an EN60320/IEC320
appliance inlet.
The socket outlet must be near to the unit and easily accessible. You
I
can only remove power from the unit by disconnecting the power
cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions
I
according to IEC 950. The conditions are only maintained if the
equipment to which it is connected also operates under SELV
conditions.
Switzerland only:
I
The supply plug must comply with SEV/ASE 1011.
The cord set must be UL-approved and CSA certified.
I
The minimum specification for the flexible cord is:
I
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
I
10A.
The attachment plug must be an earth-grounding type
I
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A,
250V) configuration.
The supply plug must comply with section 107-2-D1,
I
standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
I