Bunn Axiom Series Service & Repair Manual page 43

Table of Contents

Advertisement

BLK-14
LIMIT
THERMOSTAT
BLK-14
WHI
BLK
BLU-14
RELAY
BLK-14
WHI
J1-1
BLK
WHI/BLU
J1-5
WHI/RED
WHI/GRN
J1-10
CONTROL SWITCH ASSY
STATIC
J2-1
SHIELD
J2-6
B1
A6
D1
J2-10
BRN
J3-1
GRN
BLU
J3-3
WHI
J9-1
BLK
120V AC 2 WIRE
120/208V AC 3 WIRE
120/240V AC 3 WIRE
SINGLE PHASE
SCHEMATIC WIRING DIAGRAM
SINGLE AXIOM - 15, 20 & 35
BLU-14
"KEEP WARM" HEATER
(NOTE – ALL WARMERS ARE NOT
AVAILABLE ON ALL MODELS!)
A3
D2
A4
D3
A5
B2
LEVEL PROBE
(SHORT)
LEVEL PROBE
t
(LONG)
29077.0019A 03/09 ©2009 BUNN-O-MATIC CORPORATION
Page 43
MAIN ON/OFF SWITCH
TANK HEATER
BLK-14
BREW STATION WARMER
(CONTROLLED BY ENABLE BREW SW)
WHI/RED
DISPENSE
WHI/GRN
SOL
L1
L2
GREEN
(Late 20 & 35
Models only)
BLK Model 20 & 35
WHI-14 Model 20
RED-14 Model 35
WHI Model 15
WHI
WHI
REFILL
WHI
WHI/BLU
SOL
WHI
WHI
CONTROL SWITCH ASSY CODES
BREW WARMER
A3
HALF
A5
FULL
A6
START BREW
A4
LEFT HIDDEN
B1
RIGHT HIDDEN
B2
"DIGITAL"
D1
"BREWER"
D2
"CONTROL"
D3
N
39132 041708

Hide quick links:

Advertisement

Table of Contents
loading