Programming Level 3 - Bunn Axiom Series Service & Repair Manual

Table of Contents

Advertisement

CAL TEMPERATURE
NO SENSOR? YES
200°
CAL
200°
(-)
DONE
(+)
% LimeAdjust OFF
(-)
DONE
(+)
LP1 LP2 OZ 4.50
(-)
DONE
(+)
SPRAY OZ/M:
##.#
(-)
DONE
(+)
CALIBRATE FLOW ?
NO
YES
PROGRAMMING - LEVEL 3
Allows technician to calibrate after probe and/or control board replace-
ment. Select "YES".
NOTE: Tank temperature must be within range (192° - 208° F)
VIDEO CLIP: Calibrate Temp Click - >
Insert an accurate thermometer approximately 10˝ into tank. Adjust the
number on the right with +/- until it matches reading of thermometer.
Select "DONE"
This screen allows adjustment of the lime compensation system when
BrewLOGIC is turned on.
Range: 2 - 50. Default: 10% variation of brewed volume.
The remaining screens in Level 3 are just a convenient shortcut to the
same ones used in previous levels.
VIDEO CLIP: Calibrate sprayhead fl ow
rate with BrewLogic on Click - >
VIDEO CLIP: Calibrate sprayhead fl ow
rate with BrewLogic off Click - >