Number
Mnemonic
240.
KERNEL-4-WARNING
241.
KERNEL-4-WARNING
242.
KERNEL-4-WARNING
243.
KERNEL-4-WARNING
244.
KERNEL-4-WARNING
245.
KERNEL-4-WARNING
246.
KERNEL-4-WARNING
247.
KERNEL-4-WARNING
248.
KERNEL-4-WARNING
249.
KERNEL-4-WARNING
250.
KERNEL-4-WARNING
251.
KERNEL-4-WARNING
252.
KERNEL-4-WARNING
253.
KERNEL-4-WARNING
Severity
Syslog Message
4
Update_MU_State : wrong
IP version
4
"PAL_ESS_Data : de-auth
""MACSTR"" tx'ing on
wrong radio:""MACSTR""
should be on""MACSTR
4
"pshandle:de-authing
""MACSTR"". unknown src-
addr in ctl frame
4
received unconfigured
VLAN id %d
4
pal: Send_2_CC call failed
for a deauth-req
4
pal: Send_2_CC call failed
for mu-remove-req
4
warning: rx data from
unknown portal
4
Unreal dt( tx_pkt ) @ rate
%d: 0x%08lx - 0x%08lx =
0x%08lx\
4
Unreal dt( retry ) @ %d:
0x%08lx - 0x%08lx =
0x%08lx
4
Unreal delta tx-fail:
0x%08lx - 0x%08lx =
0x%08lx
4
"capwap skb length
underrun: received %d,
expected %d
4
"radio ""MACSTR"" lost first
frag of seq %04x till %04x
4
"radio ""MACSTR"" lost seq
%u to %u
4
warning: unable to queue
skb
Syslog Messages & MU Disassociation
Meaning / Cause
Wrong IP address information within
an update MU state request. Validate
IP address information (if necesary)
and
re-attempt request.
De-authentication was the result of a
transmission on a wrong (undefined)
radio.
Unknown address in a control frame
results in deauthentication.
A unconfigured VLAN ID was
received. Interoperations with this
VLAN requires the correct ID.
An MU association removal request
has failed. Attempt to remove the MU
again.
Data has been received from an
unknown portal location. This is an
informational warning and should be
checked periodically to ensure its not
repeated and the source represents a
viable threat.