Clearances To Combustibles; Installation Considerations - Quadra-Fire YOSEMITE-MBK Owner's Manual

Yosemite series non-catalytic, front/side load, wood heater installation and operation
Hide thumbs Also See for YOSEMITE-MBK:
Table of Contents

Advertisement

Yosemite Wood Stove
B. Clearances To Combustibles (UL And ULC)
E1
B
A
Non-fuel
F1
C2
door side
C1
D2
D1
Fuel Door
side
Fuel door
Non-fuel
side
door side
Alcove
Vertical
IF SIDE FUEL LOADING DOOR IS NOT USED:
• It must remain in the locked position at all times
• Use clearances for non-fuel door side for both sides
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
TOP VENT VERTICAL
A
B
C1
Single Wall-USA
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A
Single Wall-Canada
12.5(316) 9(229) 19.5(495) 27.5(699) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
Double Wall-USA
10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
Double Wall-Canada 10.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406)
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
Double Wall-USA
11.5(330) 8(203)
19.5(495) 25.5(648) 10(254) 16(406)
Double Wall-Canada 11.5(330) 8(203)
19.5(495) 27.5(699) 10(254) 18(457)
90
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
O
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
Double Wall-USA
11(279) 7.5(191) 19.5(495) 25.5(648) 10(254) 16(406) N/A
Double Wall-Canada
11(279) 7.5(191) 19.5(495) 27.5(699) 10(254) 18(457) N/A
ALCOVE -
Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)
Front Door
Side Door-USA
Side Door-Canada
Double Wall-USA
11.5(292) 8(203) 19.5(495) 25.5(648) 10(254) 16(406) N/A
Double Wall-Canada 11.5(292) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL:
listed double wall air insulated connector pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home
must be equipped with a spark arrestor). Additional specifications include a MAXIMUM 10" (254mm) MANTEL WIDTH and the following
clearances. Accessory Horizontal Heat Shield, Part HTSHLD-7006, is required for rear vent installations.
Double Wall-USA
N/A
4(102) 19.5(495) 25.5(658) 10(254) 16(406) N/A
Double Wall-Canada
N/A
4(102) 19.5(495) 27.5(699) 10(254) 18(457) N/A
*NFPA MINIMUM CLEARANCE - NOT TESTED
Page 10
Max Mantel Depth
10" (254mm)
G
F2
Ceiling
G*
E2
Mantel
Vertical then Horizontal
Horizontal
C2
D1
D2
E1
E2
F1
F2
N/A
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
N/A
59(1499) 18*
N/A
N/A
N/A
59(1499) N/A
N/A
N/A
N/A
59(1499) N/A
N/A
N/A
N/A
59(1499) N/A
N/A
N/A
N/A
59(1499) N/A
Max Depth
Min Width
Min Height
48(1219)
44(1118)
54(1372)
48(1219)
56(1422)
54(1372)
48(1219)
60(1524)
54(1372)
N/A
N/A
N/A
42(1067) N/A
N/A
N/A
N/A
42(1067) N/A
Six inch (6") (152mm) diameter
N/A 30(762) ceiling N/A
N/A
N/A
N/A 30(762) ceiling N/A
N/A
N/A
USA or Canada - Single or Double Wall Pipe: 21(533) mantel
7004-187H
R
4
H
A. Hearth Protection Requirements
G
Ceiling
FLOOR PROTECTION: Floor protector must be non-
combustible material, extending beneath heater and to the
front, sides and rear as indicated. The floor must be non-
combustible or otherwise adequately protected from radiant
heat given off by the unit and from sparks and falling embers.
A layer of thin brick or ceramic tile over a combustible floor
is not sufficient.
In US installations, it is necessary to install a floor protec-
tor a minimum of 16 inches (406mm) in front of glass and 8
inches (203mm) to both sides of the fuel loading door. Open
the door and measure 8 inches (203mm) from the side edge
of the opening in the face of the appliance. *See exception.
G
H
8"
(200mm)
Figure 11.3
June 23, 2011
June 23, 2011
R

Installation Considerations

In Canada, similar floor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *See exception.
*ExCEPTION: Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 11.4.
SIDE FUEL DOOR LOCKED SHUT
10-1/2"
(267mm)
Front Fuel
loading door
36-3/4
"
(933mm)
Minimum
8"
16" (406mm) from fuel
(200mm)
loading door
USA
33"
(838mm)
Minimum
Figure 11.1
BOTH FUEL DOORS ACCESSIBLE
8"
(200mm)
Fuel loading doors
Side
Front
36-3/4"
(932mm)
Minimum
Minimum 16"
(406mm) from
fuel loading
door
USA
44-1/2"
(1130mm)
Minimum
7004-187H
Yosemite Wood Stove
WARNING
Fire Risk.
• Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
200mm (8")
200mm
200mm
1187mm
(8")
(8")
(46-3/4")
Minimum
450mm (18")
CANADA
1010mm (39-3/4") Minimum
Figure 11.2
200mm
(8")
200mm
Fuel loading doors
(8")
Side
Front
1187mm
(46-3/4")
Minimum
Minimum 450mm
(18")
from each
fuel loading door
CANADA
(49-3/4")
1264mm
Minimum
Figure 11.4
Page 11