Table Of Contents - Quadra-Fire YOSEMITE-MBK Owner's Manual

Yosemite series non-catalytic, front/side load, wood heater installation and operation
Hide thumbs Also See for YOSEMITE-MBK:
Table of Contents

Advertisement

Yosemite Wood Stove
and Welcome to the Quadra-Fire Family
H
earth & Home Technologies welcomes you to our tradition of
excellence! In choosing a Quadra-Fire appliance, you have our
assurance of commitment to quality, durability, and performance.
This commitment begins with our research of the market, including
'Voice of the Customer' contacts, ensuring we make products that
will satisfy your needs. Our Research and Development facility
then employs the world's most advanced technology to achieve
the optimum operation of our stoves, inserts and fireplaces. And
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
LABEL IS LOCATED ON THE BACK OF THE STOVE
CAUTION:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN
BURNS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE
NAMEPLATE AND INSTRUCTIONS.
R
Tested and
O-T L
Portland
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
TESTED TO:
Report: #061-S-54-2
UL 1482, UL737, ULC S627-00
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE
HOMES. (UM) 84-HUD .
"For Use with Solid Wood Fuel Only"
SINGLE WALL:
Six inch (6") (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built UL103
PREVENT HOUSE FIRES
HT Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
Install and use only in accordance with manufacturer's
DOUBLE WALL:
Six inch (6") (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103 HT Class
installation and operating instructions. Contact local building or
fire officials about restrictions and installation inspections in
"A" chimney, or a masonry chimney and the referenced clearances.
your area. Do not obstruct the space beneath heater.
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree Factory-built chimneys.
WARNING - For Mobile Homes: Do not install in a sleeping
room. An outside combustion air inlet must be provided and
MOBILE HOME:
Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be
unrestricted while unit is in use. The structural integrity of the
equipped with a spark arrestor. Apply double wall clearances below when installing unit.
mobile home floor, ceiling and walls must be maintained. The
stove needs to be properly grounded to the frame of the mobile
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
home. Components required for mobile home installation:
Outside Air Kit, Part Number 831-1780.
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
Refer to manufacturer's instructions and local codes for
TOP ENT ERTICAL
A
B
C1
precautions required for passing chimney through a
combustible wall or ceiling and maximum offsets.
Single Wall-USA
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A
Inspect and clean chimney frequently - Under Certain Conditions of
Use, Creosote Buildup May Occur Rapidly.
Single Wall-Canada
12.5(316) 9(229) 19.5(495) 27.5(669) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
Do not connect this unit to a chimney serving another
appliance.
Double Wall- USA
10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
Optional Components: Optional Blower, Part 831-1701.
Double Wall-Canada 1 0.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route cord under or
in front of appliance.
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
DANGER: Risk of electrical shock. Disconnect power supply
before servicing.
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A
Replace glass only with 5mm ceramic available from your dealer.
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
Do not use grate or elevate fire. Build wood fire directly on
firebrick.
Double Wall-USA
11.5(330) 8(203) 19.5(495) 25.5(648) 10(254) 16(406)
Do not overfire - if heater or chimney connector glows, you are
overfiring.
Double Wall-Canada 11.5(330) 8(203) 19.5(495) 27.5(699) 10(254) 18(457)
Operate only with the fuel loading door closed. Open only to
add fuel to the fire.
**NFPA MINIMUM CLEARANCE - NOT TESTED
FLOOR PROTECTION*:
Side fuel loading door locked shut
Both fuel loading doors accessible
Floor
protector
must
be
8"
(203mm)
non-combustible
material
or
equivalent, extending beneath
heater and to front/sides/rear as
Fuel loading doors
Front Fuel
36-11/16
"
Front
Side
loading door
indicated
on
the
diagram.
(932mm)
36-11/16
"
Minimum
(932mm)
Exception: Non-combustible floor
Minimum
Minimum 16"
8"
8"
C1
protections must extend beneath
(406mm)
from
16"
(406mm)
from fuel
(203mm)
(203mm)
fuel loading
D1
the flue pipe when installed with
loading door
door
Non-fuel
USA
USA
horizontal venting and extend 2"
door side
44-1/2
"
Minimum
33"(838mm) Minimum
(51mm) beyond each side.
(1130mm)
*In Canada: Must be minimum 18"(450mm) in front of both fuel loading
doors and 8" (200mm) on both sides and back.
Mfg by
2010 2011 2012 Jan. Feb.
Mar.
Apr. May June
1445 N. Highway, Colville, WA 99114
DO NOT REMOVE THIS LABEL
www.quadrafire.com
Page 2
!
yet we are old-fashioned when it comes to craftsmanship. Each
unit is meticulously fabricated and gold and nickel surfaces are
hand-finished for lasting beauty and enjoyment. Our pledge to
quality is completed as each model undergoes a quality control
inspection.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.
Serial Number
SERIAL NO.
YOSEMITE
007
VENT SPECIFICATIONS:
Model Name
C2*
D1
D2*
E1
E2*
F1
F2*
G
H
Testing Lab &
Report Number
N/A
N/A
N/A
59(1499) 18**
N/A
N/A
N/A
59(1499) 18**
N/A
N/A
N/A
N/A
59(1499) 18**
N/A
N/A
N/A
N/A
59(1499) 18**
SEE MANUAL FOR OTHER CONFIGURATIONS
H
E1
B
A
Non-fuel
F1
G
C2
door side
F2
D2
Fuel Door
E2
side
Fuel door
side
July Aug. Sept. Oct. Nov.
Dec.
Mfg. Date
U.S. ENVIRONMENTAL PROTECTION AGENCY -
Certified to comply with July 1990 particulate emission
standards.
Made in U.S.A.
7004-188
7004-187H
R
Safety Alert Key:
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the fireplace or to property.
A. Appliance Certifications ......................4
B. Mobile Home Approved ......................4
C. Glass Specifications ............................4
Considerations ....................................5
B. Fire Safety ..........................................5
C. Negative Pressure ..............................6
D. Flue Draft Considerations ...................7
E. Venting Systems .................................7
and Pre-Burn Check List.....................7
H. Typical Stove System .........................8
Section 3: Dimensions & Clearances
A. Appliance Dimensions ........................9
Section 4: Installation Consideration
A.
Hearth Requirements .........................11-12
B.
Reversible Flue Collar ........................13
C.
Horizontal Flue Heat Shield ................13
D.
Leg Leveling System ..........................14
E.
Mechanism .........................................14
F.
Outside Air ..........................................15
G. Optional Blower Installation ................15
Section 5: Chimney Requirements
A. Venting Components ..........................16
B. Chimney Systems ...............................16-19
C. Installing Chimney Components .........19
D. Chimney Termination Requirements ..20
E. 2-10-3 Rule ..........................................20
June 23, 2011
June 23, 2011
R

TABLE OF CONTENTS

Section 6: Mobile Home ...............................
A. Door Handle Assembly .......................22
B. Blower Speed Adjustment ..................22
A. Overfiring Your Appliance ...................23
B. Wood Selection & Storage ..................23-24
C. Burning Process ..................................24-25
E. Air Controls .........................................25
F. Heat Output Settings ...........................26
G. Burn Rates ..........................................26
H Building A Fire .....................................26
I.
J. Opacity (Smoke) .................................27
K. Clear Space ........................................28
M. Correct Baffle & Blanket Position ........29
Section 9
:
C. Firebrick Inspection & Replacement ...32
D. Glass Replacement .............................32
Section 10: Troubleshooting ........................
Section 11: Reference Material
A. Exploded Drawings .............................36
B. Service Parts & Accessories...............37-40
C. Service & Maintenance Log ................41
D. Warranty Policy ...................................42-43
E. Contact Information .............................44
7004-187H
Yosemite Wood Stove
21
Materials .............................................25
35
Page 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yosemite-pmh

Table of Contents