PRODUCT DIMENSIONS AND CLEARANCES

These Monogram free-standing refrigerators require the
following clearances for proper air circulation, plumbing
and electrical connections.
Air Circulation Clearances:
• 1/8" on each side
• 1/2" at the back side

THE INSTALLATION SPACE

The opening width must be at least 36".
36" min.
Electrical
70" min.
Water Supply
Planning Information
69-5/8"
Depth Including Handles
29-1/2" - Tubular Handles
30-1/4" - Professional Handles
Wall View
Area
27-1/2"
35-7/8"
Depth
Case Width
35-7/8"
Installation in a corner:
• Allow 4" clearance on each side to an adjacent wall for a
90° opening and access to drawers.
• Allow 15" clearance to wall on each side for removal
of drawers.
Water And Electrical Locations
The opening must be prepared with the electrical and
water supply located as shown.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
NOTE: GFI (ground fault interrupter) is not recommended.
• The cold water line can enter the opening through the
floor or through an adjacent cabinet, as close to the back
wall as possible. The water line should be GE
SmartConnect
tubing between the cold water line and water connection
location at the rear of the refrigerator. Installation of an
easily accessible shut off valve in the water line is
recommended.
3
Refrigerator Tubing or 1/4" O.D. copper