PRODUCT DIMENSIONS
AND CLEARANCES
35-7/8"
|
27-1/2" |
CaseWidth -'_
Depth d
/
69-5/8"
35-7/8"
/
DepthIncludingHandles ._//z
29-1/2"- TubularHandles
30-1/4"- Professional H andles
These Monogram free-standing refrigerators require the
following clearances for proper air circulation, plumbing
and electrical connections.
Installation in a corner:
. Allow 4" clearance on each side to an adjacent wall for a
90 ° opening and access to drawers.
Air Circulation Clearances:
.1/8" on each side
.1/2" at the back side
_15
F15'!
...................................
!il,
g0° DoorSwing
I
I
I
JL
24-5/8"
. Allow lS" clearance to wall on each side for removal
of drawers.
THE INSTALLATION
SPACE
The opening width must be at least 36".
70" min.
36" min.
Electrical
Area
Water Supply
Wall View
Water And Electrical Locations
The opening must be prepared with the electrical and
water supply located as shown.
Additional Specifications
. A !!5 volt 60Hz., !5 or 20 amp power supplu is required.
An individual properlu grounded branch circuit or circuit
breaker is recommended. Install a properlu grounded
3-prong electrical receptacle recessed into the back wall.
NOTE:GFI (ground fault interrupter)is not recommended.
. The cold water line can enter the opening through the
floor or through an adjacent cabinet, as close to the back
wall as possible. The water line should be GE
SmartConnect
TM
Refrigerator Tubing or 1/4" O.D.copper
tubing between the cold water line and water connection
location at the rear of the refrigerator. Installation of an
easily accessible shut off valve in the water line is
recommended.