Hitachi UC 9SD Technical Data And Service Manual page 12

Charger
Table of Contents

Advertisement

(3) Failure Mode (C) Steps and Repair Procedures
Abnormal heat is
generated.
Does the Pilot
Lamp go off
after completion
of charging?
Is the heat
generated by
the battery or
the charger?
Is the heat
generated by the
Transformer?
Printed Circuit Board
is defective.
Replace Printed
Circuit Board.
NO
YES
NO
Warming of the battery in the
final stage of charging is normal.
YES
Charger
YES
NO
Battery
--- 10 ---
To Failure Mode (B)
Replace battery.
Replace Transformer.
* 7.2 V batteries cannot
be charged.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uc 12sd

Table of Contents