(1) Failure Mode (A) Steps and Repair Procedures
Follow proper
charging procedures.
Remove dirt or
correct abnormality.
Charge at appropriate
temperature.
10 C --- 40 C
(50 F --- 104 F)
Battery cannot be
charged if over
40 C (104 F).
Cool battery before charging.
Check with tester.
Pilot Lamp on,
Charger does not go on.
NO
Is battery charged
according to proper
procedures ?
YES
Are connection
YES
terminals on Charger
or battery dirty,
deformed or
abnormal?
NO
Is the
temperature range
NO
appropriate for charging?
10 C --- 40 C
(50 F --- 104 F)
YES
YES
Is the battery
too hot?
NO
What is the
voltage of the battery
between the (+) and (-)
terminals and (+) and
(T) terminals?
DC 0 V
Battery is defective.
Replace battery.
Defective Charger
Is there
continuity between
the blades of the
AC Plug?
YES
Is the fuse on
the secondary side
blown?
NO
Is there a
disconnected lead
wire on the secondary
side?
NO
DC 9.6 V
Printed Circuit Board
is defective.
Replace Printed
Circuit Board.
--- 8 ---
Circuit break
Is there a break
in the Cord?
NO
NO
Replace Transformer.
Thermal fuse on
primary side of
Transformer is melted.
Replace Cord.
YES
Replace fuse.
* 7.2 V batteries cannot
be charged.
YES
Replace Transformer.
YES