3.3.2. Door aperture with compressor switched on
If one of the doors is opened while the compressor is in operation, the fans are switched off.
If the door is not re-closed after two minutes, the fans are switched on again.
compressor
fans
doors
3.3.3. Aperture of door with compressor switched off
If one of the doors is opened while the compressor is not in operation, during the period of 30 minutes in
which the fans are switched off, the fans will switch on again for two minutes from the moment the door is
closed.
Thereafter, the fans switch off automatically.
compressor
fans
doors