3.3. Fans

The two fans operate in parallel, but have different functions. The evaporator fan circulates cold air through
the appliance; the second fan is used to cool the condenser.
Both fans are powered at 21V DC or 24V DC, depending on the climate class (N or T).
evaporator fan
condenser fan
The fans are actioned (switched on and off) according to the operation of the compressor and the aperture or
closure of the doors.

3.3.1. Operation with doors closed

When the compressor switches on, the fans, too, are switched on. After the compressor switches off, the
fans continue to operate for two minutes, then switch off. As the refrigerator compartment is cooled only by
the cold air ducted in by the evaporator fan, the fans switch on again after 30 minutes even if the compressor
remains off.
compressor
fans
Eurocombi