Miele G 7804 Operating Instructions Manual page 53

Washer-disinfector
Table of Contents

Advertisement

,
The inlet hose must not be
shortened or damaged in any way
(see illustration).
See also the installation diagram
supplied.
AD-water connection (pressurised)
>50-1000 kPa (0.5-10 bar)
The machine is supplied as standard
for connection to a supply system of
0.5 - 10 bar (50 - 1000 kPa). If the water
flow pressure is below 2 bar (200 kPa)
the fill time is automatically extended.
– The AD pressure tested hose
(marked "H
O pur") with a 3/4"
2
threaded union must be connected
to the on-site AD stopcock for
purified water.
If the AD water connection is not
going to be used, the electronics will
need to be reprogrammed by a
Miele Service Technician. The inlet
hose will remain on the rear of the
machine.
AD water connection (non-pressu-
rised) 8.5 - 50 kPa (0.085 - 0.5 bar)
- Option -
NOTE:- NON Pressurised is Standard
for Models Sold in Australia.
Optional connection all other
countries.
The appliance has to be converted for
connection to 8.5 - 50 kPa if this was
not done at the factory (special
version). The installation of a feed
pump should only be carried out by
Miele Service.
When the AD water container is
non-pressurised, the tank outlet has
to be at least the height of the upper
edge of the machine (see installation
instructions).
Plumbing
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents