Setting The Regeneration Level - Electrolux Diva EDW 2000 Service Manual

With electronic control 60 cm
Hide thumbs Also See for Diva EDW 2000:
Table of Contents

Advertisement

7.2 Setting the regeneration level

The count for "as needed" execution of the regeneration cycle is made by the electronic control
system based on the duration of the fill phases and thus on the quantity of water loaded (and not on the
number of cycles executed).
The adjustment is made over 10 levels. If level [1] is selected, regeneration is not performed and the
salt LED does not light.
1. Turn on the appliance by pressing the S0 button
LED LD0 lights up
The appliance is automatically set to the selection mode
2. Simultaneously press and hold down the S1 and S2 buttons:
LED LD0 is lit
LEDs LD1, LD2 and LD3 begin to flash, which shows the machine will accept new programming
3. Press the S1 button to call up this function:
LED LD0 is lit
LED LD1 continues to flash
LEDs LD2 and LD3 turn off
the display shows the current setting
see the table listing the regeneration values
4. When the S1 button is pressed repeatedly:
LED LD0 is lit
LED LD1 continues to flash
the display shows the current setting
the regeneration level is increased stepwise until it reaches 10L
5. To store the new setting:
Shut off the appliance using the S0 button
Wait 60 seconds
LED LD0 is lit
All the indicators on the control panel shut off
SOI/TD - PR
35
599 35 94-03