hIGh ELEVAtIONS
Input ratings are shown in BTU per hour and are certified without deration for elevations
up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installation must be in accordance with
the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for instal-
lation at elevations above 4,500 feet (1,370 m).

ORIFIcE SIZES, pRESSuRES AND Btus

NAtuRAL GAS
Manifold Press: (W.C.)
Maximum Supply Pressure 10.5"
Minimum Supply Pressure 4.5"
Model Number
(Millivolt/Electronic/SCS)
Max. Btu/hr Input
Min. Btu/hr Input
Orifice size
BEFORE yOu StARt
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incom-
plete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should
have the following:
• Fireplace (Firebox and Burner System)
• Rock Wool
• Log Set
ItEMS REquIRED FOR INStALLAtION
tools:
• Phillips Screwdriver
• Hammer
• Saw and/or saber saw
• Level
• Measuring Tape
• Electric Drill and Bits
• Pliers
• Square
• Pipe Wrench
6
pROpANE GAS
3.5"
Manifold Press: (W.C.)
Maximum Supply Pressure
Minimum Supply Pressure
BDV300V/E/S
Natural
Propane
21,000
21,000
15,000
15,000
#43
#54

pRE-INStALLAtION INFORMAtION

10"
13"
11"
BDV400V/E/S
Natural
Propane
24,000
24,000
17,000
17,000
#41
#53
Building Supplies:
• Framing Materials
• Wall Finishing Materials
• Caulking Material (Noncombustible)
• Fireplace Surround Material (Noncombustible)
• Piping Complying with Local Codes
• Tee Joint
• Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
BDV500V/E/S
BDV600V/E/S
Natural
Propane
Natural
26,000
26,000
26,000
20,000
20,000
20,000
#40
1.55mm
#40
Propane
26,000
20,000
1.55mm