Monessen Hearth BWB400 Series Installation, Operation And Maintenance Manual

Monessen Hearth BWB400 Series Installation, Operation And Maintenance Manual

36 inch built-in wood burning fireplaces

Advertisement

BWB400, BWB400I, BWBC400
BWBC400I W
I
NSTALLATION
BWB400-SERIES
(
)
RADIANT TYPE
T
HESE FIREPLACES ARE
"S" S
WITH
ERIES CHIMNEY SYSTEM COMPONENTS
O
M
DYS24/18(N,P)(M,V) U
NLY
ODELS
S
WITH THE
TANDARD
. 075629
FIREPLACE
.
OPENING
OOD
, O
PERATION AND
®
U. L.
LISTED FOR USE
F
U
R
OR
NVENTED
OOM
HOOD MUST BE INSTALLED WHEN MANTLE IS INSTALLED AT
B
URNING
M
36 I
B
NCH
UILT
(
GLASS DOORS
COMBUSTION AIR KIT AVAILABLE
.
G
L
S
NVENTED
AS
OG
H
ANSI Z21.11.2,
EATERS
F
IREPLACES
AINTENANCE
-I
W
B
N
OOD
URNING
,
,
FAN ASSEMBLY
.)
(
CIRCULATING TYPE
ETS WHICH HAVE BEEN FOUND TO COMPLY
ARE TO BE INSTALLED IN THIS
12"
AND
M
ANUAL
F
.
IREPLACES
AND OUTSIDE
BWBC400-
SERIES
)
FROM FIREPLACE
53D9031. Rev 1 03/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BWB400 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Monessen Hearth BWB400 Series

  • Page 1 BWB400, BWB400I, BWBC400 BWBC400I W NSTALLATION BWB400-SERIES RADIANT TYPE U. L. HESE FIREPLACES ARE "S" S WITH ERIES CHIMNEY SYSTEM COMPONENTS DYS24/18(N,P)(M,V) U ODELS WITH THE TANDARD . 075629 FIREPLACE HOOD MUST BE INSTALLED WHEN MANTLE IS INSTALLED AT OPENING...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS You have chosen the finest wood burning fireplace available. Your fireplace has been designed for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace. Listing and Code Approvals ...2 Important Information ...3 Operation Guidelines ...4 Clearances ...
  • Page 3 This fireplace is designed to sit directly on a combustible floor. The fireplace must be installed with clearances to combustible building materials as specified by this manual. Only parts manufactured by Monessen Hearth Systems and labeled for use with this fireplace should be used in the installation of the fireplace except for special roof flashings that may be fabricated locally.
  • Page 4: Operation

    Monessen Hearth Systems fireplace. This results from an oil residue on the metal. Open a door or window to allow the smoke to escape.
  • Page 5: Clearances

    Because cold air infiltration may be unavoidable in some structures, Monessen Hearth Systems is not responsible for heat loss or air infiltration through or around the fireplace.
  • Page 6 LEARANCES IGURE BWB400 BWB400 BWBC400 BWBC400 BWB400I BWB400I BWBC400I BWBC400I 33 1/4" 33 1/4" 7 3/4 7 3/4 38 1/2" 38 1/2" FRAMING FRAMING DIMENSION DIMENSION FRONT VIEW FRONT VIEW SE30 ELBOW 16 1/16 25 9/16 4 5/16 9 13/16 12 3/16 NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES.
  • Page 7: Corner Installation

    IREPLACE OCATION CAUTION: Do not install fireplace over carpeting. This fireplace does not weigh more than large pieces of furniture and can normally be located near a load bearing wall without requiring additional foundations or supports. If however, the fireplace is to be trimmed with a heavy stone or brick facing and hearth extension, be sure the supporting structure is adequate.
  • Page 8: Installation Preparation

    NSTALLATION REPARATION Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above the roof of a single story wing of a two story building as shown by Figure 8.
  • Page 9 NSTALLATION REPARATION IGURE SINGLE STORY INSTALLATION WITH SINGLE STORY INSTALLATION WITH ATTIC SPACE ATTIC SPACE SC CHIMNEY CAP SC CHIMNEY CAP 3 FT. MIN. OR 2 FT. ABOVE 3 FT. MIN. OR 2 FT. ABOVE STORM COLLAR STORM COLLAR ANY POINT WITHIN 10 FT. ANY POINT WITHIN 10 FT.
  • Page 10: Floor Protection

    LOOR ROTECTION If this fireplace is installed on a combustible floor, the floor area 16 inches in front of, and 8 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension. This hearth extension may be either minimum 6-inch thick stone or brick as shown by Figure 10, a H1652 Hearth Extension Kit or a locally constructed hearth equivalent which has a "K"...
  • Page 11 LOOR ROTECTION The ability of insulating material to retard the transfer of heat may be expressed as either Thermal Conduc- tance (C), Thermal Conductivity (K), or Thermal Resistance (R). The mathematical relationship of these values and the formulas for converting one value to another is as follows: C=K divided by the material thickness (Example C = .43 divided by 1/2 (.50) C = .86)
  • Page 12 IREPLACE OMPONENTS IGURE SF36A OR SF36AI SF36A OR SF36AI FIREPLACE FIREPLACE SE30 30 SE30 30˚ 612 OR 1212 612 OR 1212 ELBOW ELBOW FLASHING FLASHING AK4 OR AK6 AK4 OR AK6 COMBUSTION COMBUSTION AIR KIT AIR KIT 53D9031. Rev 1 03/03 SCF36A OR SCF36AI SCF36A OR SCF36AI FIREPLACE...
  • Page 13: Fireplace Components

    IREPLACE OMPONENTS SEE FIGURE FOR ILLUSTRATION OF FIREPLACE COMPONENTS DESCRIBED BELOW MODEL MODEL DESCRIPTION DESCRIPTION 36-inch radiant fireplace. SF36A 36-inch insulated radiant fireplace. SF36AI 36-inch circulating fireplace. SCF36A SCF36AI 36-inch insulated circulating fireplace. GD36PB Optional 36-inch polished brass bifold glass door kit. Frame has polished brass Optional 36-inch polished brass bifold glass door kit.
  • Page 14: Fireplace Installation

    Monessen Hearth Systems dealer. Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to the Parts Diagram and List section of this manual for proper identification of parts. Do not substitute parts. Use only parts listed for use with Monessen Hearth Systems Models BWB400, BWB400I, BWBC400, and BWBC400I fireplaces.
  • Page 15: Chimney Installation

    HIMNEY NSTALLATION IGURE "A" "A" FLUE OUTLET FLUE OUTLET HEIGHT HEIGHT 2" MIN. WHEN 2" MIN. WHEN DIM."A" IS 10' DIM."A" IS 10' 2" MIN. WHEN 2" MIN. WHEN DIM."A" IS 10' DIM."A" IS 10' OR LESS OR LESS 1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass through.
  • Page 16 HIMNEY NSTALLATION IGURE CENTERLINE CENTERLINE OF CHIMNEY OF CHIMNEY IGURE SNAP LOCK CHIMNEY SNAP LOCK CHIMNEY SUPPORT SECURLY SUPPORT SECURLY TO LOWER PIPES TO LOWER PIPES BEFORE FASTENING BEFORE FASTENING SUPPORT STRAPS SUPPORT STRAPS 53D9031. Rev 1 03/03 ACTUAL ACTUAL CENTER POINT CENTER POINT ROOF PITCH...
  • Page 17: Chimney Offset Installation

    HIMNEY FFSET LBOW NSTALLATION The following are important points that should be observed when installing elbows on the fireplace: 1. The support straps of all elbows not installed directly on top of the fireplace should be nailed securely to the surrounding structure.
  • Page 18 HIMNEY FFSET AND IGURE 14-1/2" SF30 FIRESTOP SPACER IGURE SUPPORT STRAPS NOT TO PENETRATE FIRESTOP VERTICAL CHIMNEY ENCLOSURE FASTEN ALL SUPPORT STRAPS SECURELY. VERTICAL CHIMNEY VERTICAL CHIMNEY ENCLOSURE ENCLOSURE RECOMMENDED. RECOMMENDED. DIAGONAL CHIMNEY DIAGONAL CHIMNEY ENCLOSURE ENCLOSURE ACCEPTABLE. ACCEPTABLE. DIAGONAL CHIMNEY ENCLOSURE SUPPORT STRAPS...
  • Page 19: Chimney Cap Installation

    HIMNEY NSTALLATION SC C ODEL HIMNEY : The proper height as previously explained is important to assure proper draft and safety. The PECIAL chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney.
  • Page 20 HIMNEY EIGHT AND ABLE INTERMEDIATE SECTIONS HEIGHT (INCHES) 12" 18" 36" 53D9031. Rev 1 03/03 FFSET HARTS CHIMNEY SECTIONS WITH ELBOW OFFSETS ELBOW 48" OTE FOR TRAIGHT Chimney support required at 25' chimney height. OTES FOR The length of the inclined portion of the chimney between elbows must not exceed 6 feet when unsupported, or 20 feet if the chimney is supported at 6 foot intervals using either metal support straps or an LCS chimney support.
  • Page 21: Chimney Cap Chase Installation

    HIMNEY HASE The preinstalled chimney sections should be no more than 10 inches below the top of the chase. The installation should be planned so that either a two-foot or three-foot chimney section will be used for the top section. This is necessary to ensure complete engagement of the inlet air telescope and chimney cap into the top section.
  • Page 22 UTSIDE OMBUSTION : The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model AK4 combustion air kit. IGURE INSULATION RING INSULATION RING INSERT SHORTEST SIDE...
  • Page 23 UTSIDE OMBUSTION UTSIDE OMBUSTION ECOMMENDATIONS 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through the duct.
  • Page 24: Combustion Air Assembly

    OMBUSTION AK-4 C ODEL OMBUSTION 1. Remove the cover plate from the 4-inch outlet opening location on the left or right outside of the fireplace. DO NOT remove the cover if the outside air will not be connected. 2. Place the insulation ring between the AK-4 starting collar and fireplace wall and place the starting collar (4 inch) into the hole on the side of the fireplace.
  • Page 25 PPLIANCE NSTALLATION : If an unvented gas appliance is installed in the fireplace, the gas appliance must only be operated AUTION with the fireplace glass door fully open (if included). Only unvented gas log set which have been found to comply with the standard for unvented room heaters, ANSI/IAS/AGA Z21.11.2, are to be installed in this fireplace.
  • Page 26: Trim Installation

    PPLIANCE NSTALLATION IGURE INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE OUTER FIREPLACE WRAP INNER FIREPLACE WRAP INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE SIDE BRICK COMBUSTIBLE FRAMING MEMBERS FACING MATERIAL COMBUSTIBLE FRAMING TO TOP OF SPACERS.
  • Page 27 NSTALLATION Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar joints COMBUSTIBLE of masonry trim. FRAMING MEMBERS MAY BE PLACED IGURE INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE ACROSS TOP SPACERS.
  • Page 28: Glass Door Installation And Fan Accessory

    LASS NSTALLATION AND LASS NSTALLATION This fireplace has been tested and listed for use with optional Model GD36P or GD36PB glass doors. For installation of the Models GD36P or GD36PB glass doors, see the instructions provided with the doors. CCESSORY The model BWBC400 and BWBC400I Fireplaces may be equipped with a Model FA2 fan accessory.
  • Page 29: Fireplace Operation

    IREPLACE PERATION : If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open ARNING position. (See additional operation information in section titled “Operation Guidelines”.) DVANTAGES OF A These are the practical, ecological advantages of wood as a fuel. Also to be considered is the aesthetic appeal.
  • Page 30: A Few Words Of Caution

    IREPLACE PERATION You’ll need a minimum of three logs, preferably four, to make a good fire. Add kindling and new logs as needed to rekindle a dying fire. New logs should be added at the rear grate after raking the coals toward the front. D .
  • Page 31: Maintenance And Safety Instructions

    Make sure the chimney is clear from any accumulation of soot, creosote or any other debris, and that all joints are intact. Monessen Hearth Systems does not recommend chemical cleaners because some may contain elements that corrode the metal parts of the chimney or fireplace.
  • Page 32: Fireplace Maintenance

    This is normal and unavoidable. If the cracks become large enough or parts dislodge and metal behind the refractory is exposed, the refractory panels should be replaced with new panels that can be obtained from you Monessen Hearth Systems fireplace dealer. LASS AINTENANCE For glass door maintenance, see instructions provided with the glass doors.
  • Page 33 25. Don’t clean the chimney with metallic devices or chemical cleaners. 26. Don’t use the fireplace or chimney for venting wood or coal burning heaters or inserts unless approved in writing by Monessen Hearth Systems . 27. Don’t put combustibles within 24 inches of the fireplace opening "W...
  • Page 34 All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. BWB400/BWB400I MODEL FIREPLACE KEY NO.
  • Page 35: Parts Diagrams And Lists

    ARTS IAGRAM AND All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. BWBC400/BWBC400I BWBC400 BWBC400I...
  • Page 36: Warranty

    IMITATIONS AND XCLUSIONS 1. No one has authority to add to or vary this limited warranty, or to create for Monessen Hearth Systems any other obligation of liability in connection with this fireplace and accessory. 2. Monessen Hearth Systems...
  • Page 37: Warranty

    AVE A PROBLEM 1. Contact your nearest dealer. If you cannot locate your dealer, call or write Monessen Hearth Systems as indicated below. 2. If you do not receive satisfactory service from the dealer within a reasonable time, write Monessen Hearth Systems and include the date you purchased your fireplace or component, its serial number, and details of the problem you are having.
  • Page 38 OTES This page intentionally left blank. 53D9031. Rev 1 03/03...
  • Page 39 OTES This page intentionally left blank. 53D9031. Rev 1 03/03...
  • Page 40 TTENTION PPLIANCE NSTALLER LEASE RETURN THESE PERATING NSTALLATION NSTRUCTIONS TO THE ONSUMER 53D9031. Rev 1 03/03...
  • Page 41 BWB500, BWB500I, BWBC500 BWBC500I R NSTALLATION SF42 SERIES U. L. HESE FIREPLACES ARE "S" S WITH ERIES CHIMNEY SYSTEM COMPONENTS NVENTED NVENTED EATERS ANSI Z21.11.2 APPROVED H2853 C ANOPY MUST ALSO BE INSTALLED WARNING: DO NOT SET IN ANY OF THESE FIREPLACES WITH THE CHIMNEY REMOVED ESIDENTIAL PERATION AND 42 I...
  • Page 42 You have chosen a fine woodburning fireplace. These fireplaces have been designed and manufac- tured for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace. Listing And code Approvals...2 Important Information...
  • Page 43: Important Information

    The use of improper parts in the installation can be hazardous and voids the warranty offered by Monessen Hearth Systems. This fireplace is designed to burn wood. This fireplace is not designed to burn coal, unplumbed liquid fuels, unplumbed gaseous fuels or household refuse.
  • Page 44: Operation Guidelines

    Monessen Hearth Systems fireplace. This results from an oil residue on the metal. Open a door or window to allow the smoke to escape.
  • Page 45: Clearances

    LEARANCES IGURE RESIDENTIAL INSTALLATION RESIDENTIAL INSTALLATION ROUND CHIMNEY CAP ROOF FLASHING MODEL 612 FIRESTOP-MODEL SF (REQUIRES 14 1/2 X 14 1/2 OPENING) 1 3/4" MIN. AIR SPACE TO COMBUSTIBLES) CHIMNEY (2" MIN. AIR SPACE TO COMBUSTIBLES MODEL: S12 (1 FT. PIPE) S18 (18 IN.
  • Page 46 LEARANCES IGURE BWB500 BWB500 BWBC500 BWBC500 BWB500I BWB500I BWBC500I BWBC500I 37 1/2" 37 1/2" 7 7/8 7 7/8 44 1/2" 44 1/2" FRAMING FRAMING DIMENSION DIMENSION FRONT VIEW FRONT VIEW SE30 ELBOW 16 1/16 25 9/16 4 5/16 9 13/16 12 3/16 NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES.
  • Page 47 IREPLACE OCATION CAUTION: Do not install fireplace over carpeting. This fireplace does not weigh more than large pieces of furniture and can normally be located near a load bearing wall without requiring additional foundations or supports. If however, the fireplace is to be trimmed with a heavy stone or brick facing and hearth extension, be sure the supporting structure is adequate.
  • Page 48: Installation Preparation

    NSTALLATION REPARATION Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above the roof of a single story wing of a two story building as shown by Figure 8.
  • Page 49 NSTALLATION REPARATION IGURE SINGLE STORY INSTALLATION WITH SINGLE STORY INSTALLATION WITH ATTIC SPACE ATTIC SPACE SC CHIMNEY CAP SC CHIMNEY CAP STORM COLLAR STORM COLLAR 3 FT. MIN. OR 2 FT. ABOVE 3 FT. MIN. OR 2 FT. ABOVE ANY POINT WITHIN 10 FT. ANY POINT WITHIN 10 FT.
  • Page 50: Floor Protection

    LOOR ROTECTION If this fireplace is installed on a combustible floor, the floor area 20 inches in front of, and 12 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension. This hearth extension may be either minimum 6-inch thick stone or brick as shown by Figure 10, an H2066 Hearth Extension Kit or a locally constructed hearth equivalent to the H2066.
  • Page 51 LOOR ROTECTION The ability of insulating material to retard the transfer of heat may be expressed as either Thermal Conduc- tance (C), Thermal Conductivity (K), or Thermal Resistance (R). The mathematical relationship of these values and the formulas for converting one value to another is as follows: C = K divided by the material thickness (Example C = .43 divided by 1/2 (.50) C = .86)
  • Page 52 IREPLACE OMPONENTS IGURE SF42A/SF42AI 612-1212 SE30 30∞ FLASHING ELBOW 403 DUCT AK4 COMBUSTION CONNECTOR AIR ASSEMBLY CHIMNEY CAP Must use with VFK 53D9032. Rev 1 03/03 GD42B OR GD42PB SCF42A/SCF42AI GLASS DOOR KIT SF FIRESTOP SC ROUND CHIMNEY CAP FP-4-U UNINSULATED FLEX PIPE CHIMNEY...
  • Page 53: Fireplace Components

    IREPLACE OMPONENTS DESCRIPTION DESCRIPTION MODEL MODEL 42-inch non-circulating fireplace 42-inch non-circulating fireplace SF42A SF42A 42-inch insulated non-circulating fireplace with insulating outer wraps. 42-inch insulated non-circulating fireplace with insulating outer wraps. SF42AI SF42AI 42-inch circulating fireplace 42-inch circulating fireplace SCF42A SCF42A 42-inch insulated circulating fireplace with insulating outer wraps.
  • Page 54: Fireplace Installation

    Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to the Parts Diagram and List section of this manual for proper identification of parts. Do not substitute parts. Use only parts listed for use with Monessen Hearth Systems Models BWB500, BWB500I, BWBC500, and BWBC500I fireplaces.
  • Page 55: Chimney Installation

    HIMNEY NSTALLATION IGURE "A" "A" FLUE OUTLET FLUE OUTLET HEIGHT HEIGHT 2" MIN. WHEN 2" MIN. WHEN DIM."A" IS 10' DIM."A" IS 10' 2" MIN. WHEN 2" MIN. WHEN DIM."A" IS 10' DIM."A" IS 10' OR LESS OR LESS 1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass through.
  • Page 56 HIMNEY NSTALLATION IGURE CENTERLINE CENTERLINE OF CHIMNEY OF CHIMNEY IGURE SNAP LOCK CHIMNEY SNAP LOCK CHIMNEY SUPPORT SECURLY SUPPORT SECURLY TO LOWER PIPES TO LOWER PIPES BEFORE FASTENING BEFORE FASTENING SUPPORT STRAPS SUPPORT STRAPS 53D9032. Rev 1 03/03 ACTUAL ACTUAL CENTER POINT CENTER POINT ROOF PITCH...
  • Page 57: Chimney Offset Installation

    HIMNEY FFSET LBOW NSTALLATION The following are important points that should be observed when installing elbows on the fireplace: 1. The support straps of all elbows not installed directly on top of the fireplace should be nailed securely to the surrounding structure.
  • Page 58 HIMNEY FFSET AND 14-1/2" IGURE SF30 FIRESTOP SPACER SF30 FIRESTOP SPACER IGURE SUPPORT STRAPS SUPPORT STRAPS NOT TO PENETRATE NOT TO PENETRATE FIRESTOP FIRESTOP VERTICAL CHIMNEY VERTICAL CHIMNEY ENCLOSURE ENCLOSURE FASTEN ALL SUPPORT FASTEN ALL SUPPORT STRAPS SECURELY. STRAPS SECURELY. VERTICAL CHIMNEY VERTICAL CHIMNEY ENCLOSURE...
  • Page 59: Chimney Cap Installation

    HIMNEY NSTALLATION SC C ODEL HIMNEY : The proper height as previously explained is important to assure proper draft and safety. The PECIAL chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney.
  • Page 60 HIMNEY EIGHT AND ABLE STRAIGHT RUN CHIMNEY SECTIONS INTERMEDIATE HEIGHT SECTIONS (INCHES) 12" 18" 36" 53D9032. Rev 1 03/03 FFSET HARTS CHIMNEY SECTIONS WITH ELBOW OFFSETS ELBOW 12" 48" TOTAL CHIMNEY SECTIONS INCHES 18" 36" 48" OFFSET 4 1/2 15 1/2 18 1/2 30 1/2 33 1/2...
  • Page 61: Chimney Cap Chase Installation

    HIMNEY HASE The preinstalled chimney sections should be no more than 10 inches below the top of the chase. The installation should be planned so that either an 18-inch or 36-inch chimney section will be used for the top section. This is necessary to ensure complete engagement of the inlet air telescope and chimney cap into the top section.
  • Page 62 UTSIDE OMBUSTION : The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model AK4 combustion air kit. IGURE INSULATION RING INSULATION RING INSERT SHORTEST SIDE...
  • Page 63 UTSIDE OMBUSTION UTSIDE OMBUSTION ECOMMENDATIONS 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through the duct.
  • Page 64: Combustion Air Assembly

    OMBUSTION AK4 C ODEL OMBUSTION 1. Remove the cover plate from the 4-inch outlet opening location on the left or right outside of the fireplace. DO NOT remove the cover if the outside air will not be connected. 2. Place the insulation ring between the AK4 starting collar and fireplace wall and place the starting collar (4 inch) into the hole on the side of the fireplace.
  • Page 65: Gas Appliance Installation

    PPLIANCE NSTALLATION Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak ARNING out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling which can cause serious injury or death to its inhabitants. To reduce these risks to a minimum, the following important notices and instructions should be read and followed carefully.
  • Page 66 PPLIANCE NSTALLATION 8. Be sure the gas is turned off at the appliance, then turn the gas on at the cut off valve and test the gas line connections for leaks with soapy water solution or a liquid leak detector. DO NOT USE A MATCH OR OTHER FLAME SOURCE TO CHECK FOR GAS LEAKS.
  • Page 67: Trim Installation

    NSTALLATION INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE COMBUSTIBLE FRAMING MEMBERS FACING MATERIAL TO TOP OF SPACERS. IGURE INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND COMBUSTIBLE FRAMING MEMBERS FACING MATERIAL TO TOP OF SPACERS.
  • Page 68 LASS NSTALLATION AND LASS NSTALLATION This fireplace has been tested and listed for use with optional Model GD42P or GD42PB glass doors. For installation of the Models GD42P or GD42PB glass doors, see the instructions provided with the doors. SSEMBLY The model BWBC500 and BWBC500I Fireplaces may be equipped with a accessory fan Model FA2.
  • Page 69: Fireplace Operation

    IREPLACE PERATION : If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open ARNING position. (See additional operation information in section titled “Operation Guidelines”.) DVANTAGES OF A These are the practical, ecological advantages of wood as a fuel. Also to be considered is the aesthetic appeal.
  • Page 70 IREPLACE PERATION You’ll need a minimum of three logs, preferably four, to make a good fire. Add kindling and new logs as needed to rekindle a dying fire. New logs should be added at the rear grate after raking the coals toward the front. D .
  • Page 71: Maintenance And Safety Instructions

    Make sure the chimney is clear from any accumulation of soot, creosote or any other debris, and that all joints are intact. Monessen Hearth Systems does not recommend chemical cleaners because some may contain elements that corrode the metal parts of the chimney or fireplace.
  • Page 72 AINTENANCE AND IREPLACE AINTENANCE At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should be removed and the hearth area should be swept as clean as is practical. The slow absorption of moisture into the ashes over a long period of time could cause a condition which would be corrosive to the metal fireplace parts.
  • Page 73 25. Don’t clean the chimney with metallic devices or chemical cleaners. 26. Don’t use the fireplace or chimney for venting wood or coal burning heaters or inserts unless approved in writing by Monessen Hearth Systems. 27. Don’t put combustibles within 24 inches of the fireplace opening "W...
  • Page 74 EPAIR IAGRAMS AND All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. BWB500 / BWB500I MODEL FIREPLACE KEY NO.
  • Page 75: Repair Part Diagrams And Lists

    EPAIR IAGRAMS AND All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. BWBC500 / BWBC500I MODEL FIREPLACE KEY NO.
  • Page 76: Warranty

    IMITATIONS AND XCLUSIONS 1. No one has authority to add to or vary this limited warranty, or to create for Monessen Hearth Systems any other obligation of liability in connection with this fireplace and accessory. 2. Monessen Hearth Systems...
  • Page 77 AVE A PROBLEM 1. Contact your nearest dealer. If you cannot locate your dealer, call or write Monessen Hearth Systems as indicated below. 2. If you do not receive satisfactory service from the dealer within a reasonable time, write Monessen Hearth Systems and include the date you purchased your fireplace or component, its serial number, and details of the problem you are having.
  • Page 78 HIS PAGE INTENTIONALLY LEFT BLANK 53D9032. Rev 1 03/03...
  • Page 79 HIS PAGE INTENTIONALLY LEFT BLANK 53D9032. Rev 1 03/03...
  • Page 80 TTENTION PPLIANCE NSTALLER LEASE ETURN PERATING NSTALLATION NSTRUCTIONS ONSUMER 53D9032. R 1 03/03...