4L51/62 Specifications - Schwank InfraSave 4SN5 Installation & Owner's Manual

Infrared post mounted patio heater
Table of Contents

Advertisement

PROPANE:
NEVER CONNECT AN UNREGULATED GAS SUPPLY TO THE HEATER.
PRECAUTIONS:
·
Periodically check the whole system for leaks or if the smell of gas is detected.
·
Extinguish all open flames. Perform ALL leak testing outdoors.
·
Never leak test while smoking.
·
If you can not stop a leak, turn off the gas supply and call a qualified and licensed techni-
cian, or your gas supplier.
·
Only those parts recommended by the Manufacturer should be used. Substitution will void
the warranty.
·
Do not use the heater until all connections have been leak tested and are sound !!!
GAS REQUIREMENTS:
·
Maximum inlet pressure to propane regulator must not exceed 125 psi.
·
A Minimum supply pressure of 11.0" w.c. is required to maintain correct burner input.
·
The pressure regulator and hose assembly supplied with the appliance MUST be used.
Any
replacement pressure regulator and hose must conform to standards & specifications of
the Manufacturer and all local codes.
·
The installation must conform with local codes, or in the absence of local codes, with Na-
tional Fuel Gas Code.
3.2 Series 4SL5/4BL6 specifications:
·
Operating pressure
·
Inlet gas supply pressure
·
Maximum operating input rating
·
Low fire input rating
·
Effective radiant range
·
Fuel
·
Net Weight
·
Certifications
11" w.c.
minimum 5 psi / maximum 125 psi
38,000 BTUH
22,000 BTUH
8 to 20 foot circle
(affected by wind and ambient temperature)
Propane
60 lbs
CSA International US and Canada
Page 3
4SN/L5,4BN/L6 Manual
IM080630
RD: JUNE 2008
RL: 1A