2-3 Other Component Specifications

GR9FI65R5IAA
.
4-way Valve (20S)
Coil rating
Coil resistance
Electronic Expansion Valve A
Coil rating
Coil resistance / phase
Electronic Expansion Valve B-C
Coil rating
Coil resistance / phase
Defrost Valve
Coil rating
Coil resistance
Thermistor (coil sensor)
Resistance
Thermistor (compressor discharge sensor)
Resistance
Thermistor (inlet air sensor)
Resistance
Thermistor (wide tube A sensor)
Resistance
Thermistor (narrow tube A sensor)
Resistance
Thermistor (wide tube B sensor)
Resistance
Thermistor (narrow tube B sensor)
Resistance
Thermistor (wide tube C sensor)
Resistance
Thermistor (narrow tube C sensor)
Resistance
Crank case heater
Resistance
Base heater
Resistance
Ω (at 20°C)
Ω (at 20°C)
Ω (at 20°C)
Ω (at 20°C)
kΩ
kΩ
kΩ
kΩ
kΩ
kΩ
kΩ
kΩ
kΩ
Ω (at 20°C)
Ω (at 20°C)
7
LDK-41 (Coil)
V2-410060-300 (Valve)
AC 220/240 V, 50 Hz
1600 ± 5%
UKV-U030E (Coil)
DC 12 V
46 ± 3%
CAM-MD12EX(Coil)
DC 12 V
46 ± 4%
FQ-235-RK (Coil)
FDF6A-049-RK (Valve)
AC 220/240 V - 50 Hz
1273 ± 10%
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
NTC-THERMISTOR
10 at 25 °C
20W - RESISTANCE
2640 ± 10%
75W - FLEXELEC CSC2
705 ± 10%
DATA SUBJECT TO CHANGE WITHOUT NOTICE
UKV-18D31 (Valve)
ZCAM-BD15EX (Valve)

Hide quick links: