Lincoln 1100 Series Service Manual page 45

1100 series impinger conveyor ovens
Table of Contents

Advertisement

PROCEDURE FOR USE OF TIME/TEMP SIMULATOR
NOTE: For displays with Thermocouple, simulator will not work.
This is a test device used to check the Time/Temp. Display
1. Procedure for use:
Check incoming power to display at following terminals.
a) Terminal 1 to 3 should have approximately 12.5 to 15 VAC.
b) Terminal 2 to 1 should be 1/2 of the reading from 1 to 3.
c) Terminal 2 to 3 should also be 1/2 of the reading from 1 to 3.
2.
Identify Display type:
a) Type 1 has 6 dip switches and display case is 5 1/8" wide (12.8cm).
b) Type 2 has 6 dip switches and display case is 5 5/8" wide (14 cm).
c) Type 3 has 10 dip switches.
3.
Set Dip Switches as follows:
TYPE 1
TYPE 2
TYPE 3
4. WITH POWER OFF: Remove all leads from T/T display except power input on 1,2 and 3. Install simulator to
terminals 4, 7, 9, 10.
NOTE:
When on 50 Hz power dip switch number 2 must be on.
5. WITH POWER ON: Turn time and temperature adjustment pot. fully counter clockwise.
Display should read (wait 15 seconds after turning):
TYPE 1
TYPE 2
TYPE 3
6. Turn time and temperature pot. fully clockwise.
Display should read (wait 15 seconds after turning):
TYPE 1
TYPE 2
TYPE 3
7. For performance test, turn time pot. to 10:00 and temp. adjustment pot. To 540° 10° F.
a) Time reading on display of 10:00 should not fluctuate more than
b) Temperature on display reading should not fluctuate.
SWITCH, ON/OFF
1. Shut off power at main breaker.
2. Remove conveyor.
3. Remove front control compartment cover.
4. Remove wires from switch and mark for reassembly.
5. Depress spring clips on the side of switch and push out.
6. Reinstall in reverse order.
TRANSFORMER, STEP DOWN/120 VAC
1. Shut off power at main breaker.
2. Remove Conveyor.
3. Remove control compartment covers.
4. Remove wires from transformer and mark for reassembly.
5. Remove 4 mounting screws from transformer base and replace.
6. Reassemble in reverse order.
Impinger II –1100 Series Service Manual - Domestic
1
2
3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SPEED
9:30
10 SEC
9:20
10 SEC.
9:35
10 SEC.
SPEED
10:20
10 SEC
10:10
10 SEC
. 10:20
4
5
6
7
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF OFF
TEMPERATURE
475° 10° F
HHH
635° 10° F
TEMPERATURE
615° 10° F
475° 10° F
10 SEC
475° 10° F
8
9
10
ON
OFF
ON
5 seconds.
45

Advertisement

Table of Contents
loading