Page 1
Installation and maintenance guide Automatic air grease gun Model 1162 Date of issue April 2016 Form number 404628B Read manual prior to installation or use of this product. Keep manual nearby for future reference.
Safety Table of contents Explanation of signal words for safety Read and carefully observe these installation Safety ......instructions before installing, operating or troubleshooting the assembly.
(414 Bar) of pressure. applied to the trigger, the speed of the gun es and follow the hose instructions and 2 Use only Lincoln P/N 1218, 1224, 1230 will gradually increase until maximum speed warnings. or 1236 outlet whip hoses. Grease injec- is reached with the trigger fully pulled.
Appropriate use Specifications Pump ratio (max) 40:1 • The air gun was exclusively designed to Output per stroke 0.038 in (0,62 cm pump and dispense lubricant using pneu- Pneumatic inlet pressure (minimum) 40 psi (2,7 bar) matic power. Pneumatic inlet pressure (maximum) 150 psi (10,3 bar) •...
To fill the gun from To fill the gun with a To expel air pockets bulk container filler pump 1 Withdraw the follower rod from the 1 Remove head and plunger assembly from Engage the follower rod with the follower by grease tube assembly cap and engage it container tube.
Troubleshooting Conditions Possible cause Corrective action The gun doesn’t operate. No inlet air pressure. Connect air supply. The piston (7) is stuck. Disassemble the gun, inspect for damage. Replace if necessary. Air pressure is too low. Check air pressure supply. The pressure is to be higher 40 psi.
Lincoln warrants the equipment manufac- valves, 912 series lube meters, electronic Lincoln GmbH and Co. Kg, Walldorf, tured and supplied by Lincoln to be free from Germany, for your warranty rights. lube meters (980, 981, 982 series), our uni- defects in material and workmanship for a...