Mounting Drives; Check Before Mounting; Mounting Procedures; Setting Check List - Fujitsu MAH3182MC Maintenance Manual

Disk drives
Hide thumbs Also See for MAH3182MC:
Table of Contents

Advertisement

5.4

Mounting Drives

5.4.1

Check before mounting

Reconfirm if the setting terminals are set correctly according to Table 5.8 before mounting the
drive in the system cabinet. For setting terminals location, see Section 5.3.
Setting
No.
terminal
1
SCSI ID
CN2
2
Write protect
3
Motor start mode
4
Force Narrow
5
Force single ended
6
Terminal power supply
5.4.2

Mounting procedures

Since mounting the drive depends on the system cabinet structure, determine the work procedures
considering the requirements specific to each system. The general mounting method and items to
be checked are shown below.
See Subsection 4.1 for the details of requirements for installing the IDD.
1) With a system to which an external operator panel is mounted, if it is difficult to access the
connector after the drive is mounted on the system cabinet, connect the external operator panel
cable before mounting the drive.
2) Fix the drive in the system cabinet with four mounting screws as follows:
The drive has 10 mounting holes (both sides: 3 ×2, bottom: 4). Fix the drive by using
four mounting holes of both sides or the bottom. (See Figure 4.7)
Use mounting screws whose lengths inside the drive mounting frame are 4 mm or less
when the screws are tightened (see Figure 4.6).
When mounting the drive, be careful not to damage parts on the PCAs.
3) Check to ensure that the DE is not touching the frame on the system side after tightening the
screws. At least 2.5mm of clearance is required between the DE and the frame. (Indicated in
Figure 4.6)
4) When an electric driver is in use, less than device specifications must be used.
5 - 10
Table 5.8
Setting contents
(Check item)
C141-E103-01EN

Setting check list

Setting
position
¨ (SCSI ID = __)
CN2
7 - 8
5 - 6
3 - 4
1 - 2
¨ Short
CN2 9 - 10
CN2 11 - 12 ¨ Short
CN2 13 - 14 ¨ Short
CN2 15 - 16 ¨ Short
CN2 23 - 24 ¨ Short
Check
Remarks
Upper bus
(DB 8 to 15 PI)
not connected
¨ Open
¨ Open
¨ Open
¨ Open
¨ Open
MP models

Advertisement