Maytag JDS8850BD Technical Information page 8

Dual fuel slide-in range
Hide thumbs Also See for JDS8850BD:
Table of Contents

Advertisement

Component & Oven Control Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Feature
208/240 V Setting
Determines range operating
voltage (208 or 240 VDC).
Cook Tones
Determines the number and
duration of cook time
reminder chimes.
Timers Tones
Determines the number and
duration of timer reminder
chimes.
Volume
Determines volumes of cook
and timer tones.
Energy Saver Mode
Enables a 1 watt standby
feature. If no pad is pressed
within 5 minutes, the control
enters into a sleep mode.
Demo Mode
Enables a 1 watt standby
feature. If no pad is pressed
within 5 minutes, the control
enters into a sleep mode.
Service Mode
Enables access to service
menus.
Test Access
Enables access to service
menus.
Faults Access
Displays the 10 most recent
faults produced by the
controller.
Software Versions Access
Displays the software and
EEPROM revision levels.
Display Test
Illuminates all lamps on the
control.
Control Lockout
Disables the touch keypad
control and locks the oven
cavity door.
16026930
!
WARNING
Access Procedure
Press the Setup pad, then press the right ATM
pad until 208/240 displays. Press the left ATM
pad to select 208/240 V settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM
pad. Press the left ATM pad again to select
COOK TONES settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM
pad. Press the right ATM pad to scroll to TIMERS
TONES. Press the left ATM pad to select
TIMERS TONES settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM pad
to select VOLUME settings.
Press the Setup pad, then press the right ATM
pad until ENERGY SAVER displays. Press the
left ATM pad to select ENERGY SAVER mode
settings.
Press the Setup pad, then press the right ATM
pad until DEMO displays. Press the left ATM pad
to select DEMO mode settings.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left ATM
pad to select SERVICE menu options.
Press the Back and Setup pads simultaneously
for 5 seconds to lock.
Press the left ATM pad to select 208 VDC, or the
right ATM pad to select 240 VDC. Press Setup
to exit.
Press the left ATM pad to select 1 – 30 (1 chime
every 30 seconds after the initial 4 chimes), or
press the right ATM pad to scroll to 1 – 60 (1
chime every 60 seconds after the initial 4 chimes)
or 1 BEEP (no additional chimes after the initial 4
chimes). Press the left ATM pad to select the
desired setting. Press Setup to exit.
Press the left ATM pad to select 2 – 30, or 2
chimes every 30 seconds for up to 5 minutes
(after the initial chime), or press the right ATM
pad to scroll to 2 – 60, or 2 chimes every 60
seconds for up to 30 minutes (after the initial
chime), or 1 BEEP (no additional chimes after the
initial chime). Press the left ATM pad to select
the desired setting. Press Setup to exit.
Press the right ATM pad until VOLUME displays.
Press the left ATM pad. Press the left ATM pad
to select HIGH, or the right ATM pad to scroll to
MEDIUM or LOW. Press the left ATM pad to
select desired setting. Press Setup to exit.
Press the left ATM pad to enter the energy saver
mode or the right ATM pad to exit the energy
saver mode. Press Setup to exit.
Press the left ATM pad to enable the DEMO
mode or the right ATM pad to exit the DEMO
mode. Once the DEMO mode begins, press any
key to exit. Press Setup to exit, also.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to TEST menu. Press
the left ATM pad to select TEST options. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to the FAULTS menu.
Press the left ATM pad to select FAULTS
options. Press Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to the VERSIONS
menu. Press the left ATM pad to view. Press
Setup to exit.
Press and hold the Back and Enter pads for 5
seconds to enter SERVICE menu options. Press
the right ATM pad to scroll to DISPLAY TEST.
Press the left ATM pad. Press Setup to exit.
Press the Back and Setup pads simultaneously
for 5 seconds to unlock.
8
Modification Procedure
February 2006
© 2006 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jds9860bdJds9865bd

Table of Contents