GAS HOOK-UP INSTRUCTIONS

CYLINDER CONNECTION:
valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise. Do not use tools. Leak test all joints
prior to using the barbecue. A leak test must be performed annually, and each time a cylinder is hooked up, or if a part of the gas
system is replaced.
PROPANE CYLINDER INSTALLATION:
PROPANE GAS HOOK-UP:
the grommet. Insert the quick connect hose end into the regulator outlet.
NATURAL GAS HOOK-UP:
designed for natural gas and certified for outdoor use. The gas grill is designed to operate at an inlet pressure of 7 inches water
column. A regulator must be installed if the house pressure is greater than 7 inches water column. Piping and valves upstream
of the quick disconnect are not supplied.
accessible manual shut-off valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared
end of the hose must be connected to the unit as illustrated in the Natural Gas Hose Attachment diagram. These connections must
be made by a licensed gas installer. Leak test all joints prior to using the gas grill.
Connect the 20" hose from the manifold, to the side burner as illustrated in the Natural Gas Hose Attachment diagram. Connect the
supply hose to the flare connection which faces down from the side burner. Tighten all connections using two wrenches. (Do not
use thread sealer/pipe dope.)
WARNING
• The installation must be performed by a licensed gas fitter, and all connections must be leak tested before operating the grill.
• Do not route hose underneath drip pan.
• Do not route hose between space in bottom shelf and back panel.
• Do not route hose over top of rear panel.
• Ensure all hose connections are tightened using two wrenches. Do not use teflon tape or pipe dope on any hose connection.
• Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a fire.
• Leak test all the connections using a soap and water solution, as per the leak testing instructions found in this manual.

LEAK TESTING INSTRUCTIONS

DANGER
Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check
for leaks. Sparks or open flames will result in a fire or explosion, damage to property, serious bodily injury or death.
LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. Do
not smoke while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check.
1. Turn all burner controls to off. Turn supply valve on.
2. Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and
valves.
3. Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended by the customer
care department.
4. If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or
dealer. Do not use the appliance until the leak has been corrected.
5. Turn off gas supply.
Ensure that the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel
Set cylinder into the hole in the bottom shelf.
Press the nylon grommet into the side panel, and pass the hose from the side burner through
This natural gas grill is supplied with a 10ft supply hose (complete with a quick disconnect)
The quick disconnect must not be installed in an upward direction and a readily