Pump Filter

The pump filter system prevents ingress of lint or foreign objects into
the drain pump, reducing the risk of damage.
The pump filter should be cleaned regularly, every two to three
months at least.
To avoid injury, do not carry out this operation when the wash
water is at a temperature over 30ºC
To clean the filter:
Open the kickplate cover by undoing the single screw then sliding
the cover to the left to release it from its clips.
Release the drain hose and let it swing forward.
Place a container under the drain hose to collect the flow of
remaining water from the machine.
Pull the bung from the end of the drain hose and let it drain. It may
be necessary to reseal this hose and empty the container to prevent
the container from overflowing.
Loosen the filter cover by turning it slowly anti-clockwise until the
remaining water has drained away.
When all the water has drained out of the machine, turn the filter
cover several times until the filter can be completely removed.
Remove any objects caught in the filter and the drain pump.
Refit the filter by turning it clockwise.