Rdm Events - Acer Altos 21000 Series User Manual

Table of Contents

Advertisement

A.2

RDM Events

Failure time
Power off
Power on
Reboot
Remote login password fail
Remote login
Remote power off
Remote reboot
xx CPU IERR# issued
xx CPU Thermtrip# issued
xx CPU disabled
A-2
Altos 21000 Series User's Guide
Event
Description
Once heartbeat protocol stops for 30
seconds, RDM presumes that the
operating system stops and records
the current time sent by FSC/ASM.
RDM powers off the system when the
CPU temperature exceeds the fatal
threshold.
RDM powers on the system
automatically when the CPU
temperature declines to the warning
threshold - minus 10 degrees.
In Reboot mode, RDM will reboot the
system if the temperature is at a safe
degree.
In Waiting mode, if someone tries to
connect in and there is a password fail,
RDM will record this event.
In Waiting mode, someone logs in
successfully.
In Waiting mode, Remote site powers
off the system manually.
In Waiting mode, Remote site reboots
the system manually.
When system crashed, xx CPU issued
IERR# signal.
When system crashed, xx CPU issued
Thermtrip# signal.
When system crashed, if a CPU's
temperature exceeds the threshold,
RDM will disable it.

Advertisement