Toshiba HFC R407C Service Manual page 30

Super multi split type system
Hide thumbs Also See for HFC R407C:
Table of Contents

Advertisement

9.
Outdoor unit - pressure sensor data
Display
Pressure
2
(kgf/cm
G)
17
0.0
1E
1.0
25
2.0
2D
3.0
34
4.0
3B
5.0
43
6.0
4A
7.0
51
8.0
58
9.0
5C
9.5
60
10.0
63
10.5
These are sample displays. intermediate displays to those above are possible.
10. Outdoor unit - ThD1 and ThD2 sensor data
Display
Temp. °C
05
-5.0
07
0.0
09
5.0
0C
10.0
0F
15.0
12
20.0
17
25.0
1C
30.0
22
35.0
These are sample displays. Intermediate displays to those above are possible.
Display [00] signifies sensor open circuit.
11. Outdoor unit - ThS, TE, TO sensor data
Display
Temp. °C
2A
-20.0
36
-15.0
42
-10.0
51
-5.0
60
0.0
63
1.0
66
2.0
69
3.0
6C
4.0
6F
5.0
73
6.0
76
7.0
79
8.0
These are sample displays. Intermediate displays to those above are possible.
Display [00] signifies sensor open circuit.
30
Diagnostic procedure
Outdoor unit
Display
Pressure
2
(kgf/cm
G)
67
11.0
6B
11.5
6E
12.0
72
12.5
76
13.0
79
13.5
7D
14.0
81
14.5
84
15.0
88
15.5
8B
16.0
8F
16.5
93
17.0
Display
Temp. °C
28
40.0
30
45.0
38
50.0
41
55.0
4A
60.0
54
65.0
5E
70.0
68
75.0
72
80.0
Display
Temp. °C
7C
9.0
7F
10.0
82
11.0
85
12.0
88
13.0
8B
14.0
8E
15.0
91
16.0
94
17.0
97
18.0
9A
19.0
9C
20.0
9F
21.0
Display
Pressure
2
(kgf/cm
G)
96
17.5
9A
18.0
9E
18.5
A1
19.0
A5
19.5
A9
20.0
AC
20.5
BD
21.0
B4
21.5
B7
22.0
BB
22.5
BE
23.0
C2
23.5
Display
Temp. °C
7C
85.0
87
90.0
90
95.0
9A
100.0
A2
105.0
AB
110.0
B2
115.0
B9
120.0
C0
125.0
Display
Temp. °C
A2
22.0
A5
23.0
A7
24.0
AA
25.0
AC
26.0
AF
27.0
B1
28.0
B3
29.0
B6
30.0
B8
31.0
BA
32.0
BC
33.0
BE
34.0
Display
Pressure
2
(kgf/cm
G)
C6
24.0
C9
24.5
CD
25.0
D1
25.5
D4
26.0
D8
26.5
DC
27.0
DF
27.5
E3
28.0
E7
28.5
EA
29.0
EE
29.5
F2
30.0
Display
Temp. °C
C6
130.0
CB
135.0
D0
140.0
Display
Temp. °C
C0
35.0
C2
36.0
C4
37.0
C6
38.0
C8
39.0
C9
40.0
D1
45.0
D8
50.0
DE
55.0
E3
60.0
E7
65.0
EA
70.0

Hide quick links: