Air Shutter Adjustment - Natural Gas Only - Monessen Hearth iDV380NVC Installation And Operating Instructions Manual

Idv series direct vent gas fireplace insert
Table of Contents

Advertisement

IDV380/IDV490 Fireplace Insert
ADjuSt the AiR ShutteR
The venturi of the burner is equipped with an air shutter. The opening of the venturi has
been set at 1/4" for Natural Gas and fully open for Propane installation at sea level. The
burner on Natural Gas models may be adjusted for high altitude as follows:
To increase air mixture, open the shutter more. This will reduce soot formation.
Figure 36
To decrease air mixture, close the shutter. Flames will be more yellow.
Figure 37
28
AiR ShutteR ADjuStMeNt (NAtuRAl GAS ONly)
Figure 36 -
Push Adjustment Lip Up to Open Air Shutter
FP1940
air shutter part open
Figure 37 -
Pull Adjustment Lip to Close Air Shutter
FP1941
air shutter fully open
Air Shutter
FP1940
Air Shutter
FP1941
57D0016