Insert Clearances - Monessen Hearth iDV380NVC Installation And Operating Instructions Manual

Idv series direct vent gas fireplace insert
Table of Contents

Advertisement

IDV380/IDV490 Fireplace Insert

iNSeRt CleARANCeS

No combustibles (ie: drapes, doors) may be within, or swing within 36" of the front of the insert.
FP2623
Minimum 
10" (254 mm)
Hearth Should be 
Width of Face Minimum
Figure 4 -
Mantel Clearances
MANtel CleARANCeS
NOte: the combustible area above the facing must not protrude more than 3/4" from the
facing. if it does, it is considered a mantel and must meet the mantel requirements listed
in this manual.
heARth RequiReMeNtS
The insert must be installed on a noncombustible hearth extending a minimum of 12" from the
fireplace opening (local codes may require a larger hearth). The hearth must also extend to both
sides of the face.
8
22"
(559 mm)
Minimum
12" (305 mm)
32"
(813 mm)
Minimum
8" (203 mm)
FP2623
Minimum clearances
Max. 
13"
Min.
Max.
11"
Min.
3/4"
9"
13" (330 mm)
Maximum Depth
3/4" Maximum
Depth
Combustible
Facing
Minimum
8" (203 mm)
Minimum
11" (279 mm)
CleARANCeS