Air Shutter Adjustment - Monessen Hearth ILDV20NV User Manual

Ildv series direct vent gas fireplace insert
Table of Contents

Advertisement

ILDV20/ILDV30 Fireplace Insert
ADjuSt the AiR ShutteR
The venturi of the burner is equipped with an air shutter. The opening of the venturi has been
set at 1/4" for Natural Gas and fully open for Propane installation at sea level. The burner on
Natural Gas models may be adjusted for high altitude as follows:
To increase air mixture, open the shutter more. This will reduce soot formation. Figure
32
To decrease air mixture, close the shutter. Flames will be more yellow. Figure 33
8
AiR ShutteR ADjuStMeNt (NAtuRAL GAS ONLy)
Figure 32
Push Adjustment Lip Up to Open Air Shutter
FP1940
air shutter part open
Figure 33
Pull Adjustment Lip to Close Air Shutter
FP1941
air shutter fully open
Air Shutter
FP1940
Air Shutter
FP1941
83D0511

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ildv20pvIldv30nvIldv30pv

Table of Contents