Installation Information; Before You Start; Installation Planning; Clearances - Monessen Hearth iDV380NVC Installation And Operating Instructions Manual

Idv series direct vent gas fireplace insert
Table of Contents

Advertisement

iNStAllAtiON iNFORMAtiON

BeFORe yOu StARt

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents
for shipping damage and immediately inform your dealer if any damage is found. Do not install
any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all
listed parts have been received.

iNStAllAtiON PlANNiNG

Plan for the installation of your insert. This includes determining the size of fireplace in which
unit is to be installed, length of venting to be used and finishing details, and whether any optional
accessories (i.e. wall switch, or remote control) are desired. Consult your local building code
agency to ensure compliance with local codes, including permits and inspections.
The following factors should be taken into consideration:
This insert should have sufficient access for its safe operation and maintenance.
The flow of combustion and ventilation air must not be obstructed.
Minimum clearances to combustibles, such as mantels, must be maintained. Refer to Pages
8 and 9, Figures 4 and 5.
Never obstruct the front opening of the insert.
Do not install in the vicinity where gasoline or other flammable liquids may be stored.
These units can be installed in a bedroom. Refer to National Fuel Gas Code ANSI Z233.1/
NFPA 54 (current edition), the Uniform Mechanical Code (current edition), and Local Building
Codes for specific installation requirements.
iMPORtANt: your direct vent insert was designed to be installed in an existing wood
burning fireplace. the location and clearances are subject to local building codes.
iNSeRt APPliCAtiONS
Before installing the gas fireplace insert, consider the functioning needs of the fireplace. Confirm
the size of the fireplace cavity, the design of the chimney, and the availability of the gas supply
and electricity for the insert fan.
iMPORtANt: your direct vent insert is designed to be only vented vertically with a mini-
mum height of 10 feet.
When the unit is installed into a wood burning fireplace, the minimum distance the mantel can
be placed above the fireplace is governed by local building codes applicable to wood burning
fireplaces. Consult local authorities having jurisdiction for these clearances. The underside of
the mantel will become warm. Use only finishes which are heat resistant and do not discolor.

CleARANCeS

MiNiMuM FiRePlACe SiZe/CleARANCeS tO COMBuStiBleS
The dimensions shown on Pages 8 and 9,
Figures 4 and 5, are minimum clearances to
maintain when installing this heater. Follow
these instructions carefully to ensure safe
installation. Failure to follow instructions
exactly can create a fire hazard.
Maintain the following minimum clearances for service and maintenance. Refer to Pages 8
and 9.
57D0016
IDV380/IDV490 Fireplace Insert
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idv380pvcIdv490pvcIdv490nvcIdv series

Table of Contents