Error Codes

Your machine is equipped with a diagnostic system which
monitors progress and will gives visible signals if it detects unusual
circumstances.
Error Message
The green light flashes
twice every 5 seconds with
the beeper sounding.
The green light flashes
three times every 5
seconds with the beeper
sounding.
The green light flashes
once every 5 seconds with
the beeper sounding.
The green light flashes
once every 5 seconds
and continous fast beeper
sounding.
Both the green and
red lights illuminated
continuously and the
beeper sounding 5
second blasts at 10 second
intervals.
The green light flashing
rapidly and the beeper
sounding continuously.
16
Probable Error
The door is not shut
properly during steam
cooking.
Water reservoir not
correctly seated or
Water reservoir empty
or
The "O" ring is missing
from the reservoir exit
tube.
Boiler pump error.
Probe or potentiometer
fault.
Both the "Grill" knob
and "Steam oven" knob
are turned on.
The appliance has
experienced a power
cut.
The process to be done
Shut the door.
Make sure the water reservoir is correectly
seated and has adequate water in it.
Ensure the "O" ring on the exit tube is present
and has not perished.
If the error persists, isolate the appliance and
contact CDA Customer Care.
Switch off the appliance and allow to cool
before switching on again.
If the error persists, isolate the appliance and
contact CDA Customer Care.
Isolate the appliance and contact CDA
Customer Care.
Turn one of the knobs to the "0" position.
Turn off the cooking function that is in use then
turn it on again.