10-2. Outdoor Unit (RAS-24UAX, RAS-24UA-AR)

No.
Part name
1
Common
procedure
2
Running
capacitor for
compressor
3
Running
capacitor for
fan motor
4
Magnet switch
5
Spark killer
Procedures
1) Stop the operation of the air conditioner
and turn off its main power supply or
remove the power supply wires.
2) Remove the electrical parts cover.
(4 screws 4 x 10)
3) Remove the side cabinet (front).
(2 screws 4 x 10)
4) Disconnect the connecting cables after
removing 7 screws on the terminal block.
5) Remove the side cabinet (back).
(10 screws 4 x 10)
1) Remove the capacitor band. (1 screw)
2) Disconnect the lead wires from the
capacitor terminal.
1) Remove the capacitor band. (1 screw)
2) Disconnect the lead wires from the
capacitor terminal.
1) Remove the relay. (2 screws)
2) Disconnect the lead wire from the terminal.
1) Remove the spark killer. (1 screw)
2) Disconnect the lead wire from the terminal
block.
Side cabinet
(Front)
Spark killer Running capacitor
Megnet switch
– 55 –
FILE NO. SVM-01010
Remarks
Top cabinet
Electrical
parts cover
Side cabinet
(Back)
for compressor
Running capacitor
for Fan motor