8-4-4. Wiring connection
Air Inlet grille
2
1
Terminal block
Cord clamp
Screw
Terminal
cover
Screw
Fig. 8-4-5
<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing of the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to local
cords) into pipe hole on the wall.
4. Take out the connecting cable through the cable slot
on the rear panel so that it is exploded by about 15
cm long in the front side.
5. Insert the connecting cable fully into the terminal
block and secure it by screw tightly.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air
inlet grille on the indoor unit.
CAUTION
• Be sure to refer to the wiring system diagram
labeled inside the front panel.
• Check local electrical cords and also any specific
wiring instructions or limitation.
Front panel
Connecting cable
Earth line
<Stripping length of connecting cable>
10 mm
Connecting
cable
40 mm
Fig. 8-4-7
Fig. 8-4-8
<How to install the air inlet grille on the indoor unit>
• When attaching the air inlet grille, the contrary of
removed operation is performed.
– 30 –
FILE NO. SVM-01010
Fig. 8-4-6
10 mm
NOTE:
Use strand wire only.
• Wire type : More
50 mm
than 1.5 mm
(H07RN-F or 245
IEC66) or 1.3 mm
(AWG-16)
Earth line
NOTE:
Connect the earth line
to the metallic part
(i mark) located at
the side of 3P terminal.
Fig. 8-4-9