Ras-18Uk-Ar / Ras-18Ua-Ar - Toshiba RAS-24UKX Service Manual

Split wall type air-conditioner
Table of Contents

Advertisement

5-3. RAS-18UK-AR / RAS-18UA-AR

0.39m
(Connecting pipe)
12.7
O.D.:12.7mm
P
Packed valve
( 12.7)
Compressor
PH250X3-4LM
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Cross flow fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
Pressure P
P
P
P
P
exchanger interchanging
pipe T
(MPaG)
0.4
0.6
0.3
– 15 –
FILE NO. SVM-01010
T
Packed valve
( 6.35)
Capillary tube
2.0x1000S
Capillary tube
0.8x900S
Refrigerant
R-22 1.17 kg
Mark (
) means check points of Gas Leak
Fan Speed
(indoor)
T
T (°C)
T
T
10.0
High
13.0
High
2.0
Low
0.49m
(Connecting pipe)
6.35
O.D.:6.35mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
52/31
21/15
21/15