Carrier 42LUVH055N Service Manual page 41

Dc inverter hi-wall air conditioner
Table of Contents

Advertisement

9.3.5 Temperature Sensors.
Room temp.(T1) sensor,
Indoor coil temp.(T2) sensor,
Outdoor coil temp.(T3) sensor,
Outdoor ambient temp.(T4) sensor,
Compressor exhaust temp.(Te) sensor.
Measure the resistance value of each winding by using the multi-meter.
Some frequently-used R-T data for T1, T2, T3 and T4 sensor:
Temperature (℃)
Resistance Value (KΩ)
Some frequently-used R-T data for Te sensor:
Temperature (℃)
Resistance Value (KΩ)
5
10
15
20
26.9
20.7
16.1
12.6
5
15
25
35
141.6
88
56.1
36.6
38
25
30
40
50
10
8
5.2
3.5
60
70
80
90
13.8
8.7
6.9
5
60
2.4
100
3.7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

38luvh055n38luvh065n42luvh075n42luvh065n38luvh075n

Table of Contents