Carrier 42LUVH055N Service Manual page 39

Dc inverter hi-wall air conditioner
Table of Contents

Advertisement

Outdoor Fan Motor
(Model: YDK53-6N)
Measure the resistance value of each winding by using the multi-meter.
Outdoor Fan Motor
(Model: YDK100-6T)
Measure the resistance value of each winding by using the multi-meter.
Indoor Fan Motor
Model: YDK36-4C(A)
Measure the resistance value of each winding by using the multi-meter.
Position
White - Red
Brown- Black
Resistance Value
272Ω±8% (20℃)
94Ω±8% (20℃)
Position
Black - Red
Red -Yellow
Position
Black - Red
Red -Yellow
36
Resistance Value
87Ω (20℃)
162Ω (20℃)
Resistance Value
63Ω (20℃)
57Ω (20℃)